{"product_id":"schneider-electric-g80n4tm630-gopact-mccb-630a","title":"Schneider Electric G80N4TM630 GoPact MCCB 800N 4P 630 A 50 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G80N4TM630 is a 4P GoPact MCCB 800N moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It uses a TM-D thermal-magnetic trip unit with adjustable long-time overload protection (Ir 0.7...1 x In (441-630 A)) and a fixed instantaneous short-circuit trip at 10 x In (6300 A). The breaker suits general distribution duty up to 415 V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eG80N4TM630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e4P \/ 4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e630 A at 40 °C, 630 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e50 kA at 380\/415 V AC, 65 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up adjustment\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (441-630 A) — Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e10 x In (6300 A) — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection\u003c\/td\u003e\n\u003ctd\u003e1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e240 x 250 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e8.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N performance code gives this frame a 50 kA breaking capacity at 380\/415 V AC, in line with the GoPact MCCB 800N range — the H-rated 70 kA variant is the step up where available fault current is higher. The TM-D trip unit sets L overload protection at Ir 0.7...1 x In (441-630 A) and I short-circuit protection fixed at 10 x In (6300 A), so there is no field adjustment beyond the thermal dial — pick the 630 A rating to sit just above the circuit's full-load current rather than relying on trip recalibration later. Within the 800-frame, the 500 A, 630 A and 800 A versions share the same enclosure and only differ in trip rating and pickup bands.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229492777243,"sku":"G80N4TM630","price":786.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g80n4tm630-gopact-mccb-tm-d.jpg?v=1790868367","url":"https:\/\/stoklink.com\/products\/schneider-electric-g80n4tm630-gopact-mccb-630a","provider":"Stoklink","version":"1.0","type":"link"}