{"product_id":"schneider-electric-g80n4e800-gopact-mccb-800a","title":"Schneider Electric G80N4E800 GoPact MCCB 800N 4P 800 A 50 kA ETU Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G80N4E800 is a 4P GoPact MCCB 800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It uses an electronic ETU trip unit with adjustable long-time overload (Ir 0.25...1 x In (200-800 A)), adjustable short-time (Isd 1.5...12 x Ir (300-6400 A)) and adjustable instantaneous (Ii 1.5...8 x In (1200-6400 A)) protection stages. The breaker suits general distribution duty up to 415 V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eG80N4E800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e4P \/ 4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e800 A at 40 °C, 800 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e50 kA at 380\/415 V AC, 65 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eETU (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up adjustment\u003c\/td\u003e\n\u003ctd\u003e0.25...1 x In (200-800 A) — Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Isd] Short-time pick-up adjustment\u003c\/td\u003e\n\u003ctd\u003e1.5...12 x Ir (300-6400 A) — Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up adjustment\u003c\/td\u003e\n\u003ctd\u003e1.5...8 x In (1200-6400 A) — Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection\u003c\/td\u003e\n\u003ctd\u003e1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e240 x 250 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e8.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis N-rated 50 kA ETU variant trades the TM-D's fixed magnetic trip for a fully adjustable L-S-I curve: long-time Ir 0.25...1 x In (200-800 A) sets the overload point, short-time Isd 1.5...12 x Ir (300-6400 A) lets the breaker ride through brief downstream faults for selective coordination, and instantaneous Ii 1.5...8 x In (1200-6400 A) handles close-in short-circuits. That Isd stage is the main reason to choose the ETU over the TM-D on this frame — it buys a short-time delay window a fixed trip unit cannot offer. Within the 800 A ETU line, move to the 70 kA H-rated TM-D frame instead if the installation needs more raw breaking capacity rather than curve flexibility.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229492449563,"sku":"G80N4E800","price":1149.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g80n4e800-gopact-mccb-etu.jpg?v=1790868349","url":"https:\/\/stoklink.com\/products\/schneider-electric-g80n4e800-gopact-mccb-800a","provider":"Stoklink","version":"1.0","type":"link"}