{"product_id":"schneider-electric-g80h4e500-gopact-mccb800h-500a","title":"Schneider Electric G80H4E500 GoPact MCCB800H 4P 500 A 70 kA ETU Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G80H4E500 is a 4-pole GoPact MCCB800H moulded case circuit breaker rated 500 A (In) at 415 V AC (Ue), with 70 kA breaking capacity (Icu) at 380\/415 V AC. It carries an electronic ETU trip unit (functions LSI) with adjustable long-time, short-time and instantaneous protection stages, and mounts fixed with front screw-terminal connections for distribution circuits in panels and switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG80H4E500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P \/ 4D protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] \/ [Ics] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA at 380\/415 V AC, 80 kA at 220\/230 V AC (Icu = Ics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETU (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit protection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125-500 A (0.25-1 x In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Isd] Short-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187.5-6000 A (1.5-12 x Ir, adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750-6000 A (1.5-12 x In, adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Ir (4D, full neutral protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside \/ downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 250 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20…+55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-1, EN\/IEC 60947-2, EN\/IEC 60947-2 Annex H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ETU trip unit adds an adjustable short-time stage (Isd, 187.5-6000 A (1.5-12 x Ir, adjustable)) on top of the long-time (Ir, 125-500 A) and instantaneous (Ii, 750-6000 A (1.5-12 x In, adjustable)) stages, so this 500 A breaker can be set for time-graded selectivity with downstream MCCBs instead of relying on current-magnitude discrimination alone. At 70 kA Icu \/ 70 kA Ics at 380\/415 V AC, it is suited to main-incomer or large-feeder duty ahead of lower-rated distribution breakers; the fixed-ratio TM-D version in the same 800 A frame is the simpler, lower-cost choice where that adjustable short-time stage is not needed.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229490352411,"sku":"G80H4E500","price":1051.07,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g80h4e500-gopact-mccb800h-mccb.jpg?v=1790868110","url":"https:\/\/stoklink.com\/products\/schneider-electric-g80h4e500-gopact-mccb800h-500a","provider":"Stoklink","version":"1.0","type":"link"}