{"product_id":"schneider-electric-g20b4a200-gopact-mccb-200","title":"Schneider Electric G20B4A200 GoPact MCCB 200 4P 200 A 25 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B4A200 is a 4-pole GoPact MCCB 200 moulded case circuit breaker rated 200 A, built on the 200 A frame with an ultimate breaking capacity (Icu) of 25 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 12 x In (2400 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B4A200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB 25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.7 x In to 1 x In (140-200 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 12 x In (2400 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.7 x In to 1 x In (140-200 A)) lets this 200 A breaker be tuned down for loads sized below the nominal 200 A frame rating, and the instantaneous pick-up is fixed at 12 x In so the magnetic trip scales with the chosen thermal setting. Unlike the 125 A frame, this 200 A frame rates Ics at 100% of Icu (25 kA of 25 kA at 380\/415 V AC), so it can clear its full fault current repeatedly without a derated service rating — a relevant factor for sub-mains where more than one fault clearance may occur before maintenance. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471969563,"sku":"G20B4A200","price":213.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b4a200-gopact-mccb-200.jpg?v=1790868330","url":"https:\/\/stoklink.com\/products\/schneider-electric-g20b4a200-gopact-mccb-200","provider":"Stoklink","version":"1.0","type":"link"}