{"product_id":"schneider-electric-g20-25uvr240ac-undervoltage-release","title":"Schneider Electric G20-25UVR240AC GoPact MCCB 200-250 UV Release 200-240 V AC Circuit Breaker Accessory","description":"\u003cp\u003eThe Schneider Electric G20-25UVR240AC is an MN undervoltage release common to the GoPact MCCB 200 and GoPact MCCB 250, supplied from a 240 V AC 50\/60 Hz control circuit. It opens the breaker once the supply voltage drops below 0.7 times Un, with opening guaranteed below 0.35 times Un, and holds the breaker closed above 0.85 times Un. Maximum response time is 25 ms.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20-25UVR240AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct \/ Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200, GoPact MCCB 250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreshold Tripping Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35...0.7 Un opening, 0.85...1.1 Un closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Holding Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pick-up Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eFit the G20-25UVR240AC where a GoPact MCCB 200 or 250 must drop out automatically on loss or deep sag of a 240 V AC control supply, which is common on interlocked or safety-chain circuits. The opening band between 0.35 and 0.7 times Un is a possible-but-not-guaranteed zone, so trip-time coordination studies should use the 0.35 Un guaranteed-open threshold, not the 0.7 Un upper limit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54076347449627,"sku":"G20-25UVR240AC","price":47.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20-25uvr240ac-gopact-mccb-200-250-undervoltage-release.jpg?v=1790868959","url":"https:\/\/stoklink.com\/products\/schneider-electric-g20-25uvr240ac-undervoltage-release","provider":"Stoklink","version":"1.0","type":"link"}