{"product_id":"schneider-electric-e080h420fm","title":"Schneider Electric E080H420FM EasyPact CVS800H 4P 800 A 70 kA ETS 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric E080H420FM is a 800 A EasyPact CVS800H moulded case circuit breaker for low-voltage electrical distribution, built on a high-breaking H frame. Its ETS 2.0 electronic trip unit gives adjustable long-time overload and instantaneous short-circuit protection (LI), and the 4-pole, 4D frame breaks 70 kA at 380\/415 V AC under IEC 60947-2.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Reference\u003c\/td\u003e\n\u003ctd\u003eE080H420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEasyPact CVS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eLow-voltage electrical distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtected poles\u003c\/td\u003e\n\u003ctd\u003e4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003eunprotected (3D), 0.5 x Ir (3D+N\/2), or 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current [In]\u003c\/td\u003e\n\u003ctd\u003e800 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated operational voltage [Ue]\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated insulation voltage [Ui]\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated impulse withstand voltage [Uimp]\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity [Icu]\u003c\/td\u003e\n\u003ctd\u003e80 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 60 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity [Ics]\u003c\/td\u003e\n\u003ctd\u003e80 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 60 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eETS 2.0, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit rating\u003c\/td\u003e\n\u003ctd\u003e800 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eLI (long-time overload + instantaneous short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-time pickup adjustment [Ir]\u003c\/td\u003e\n\u003ctd\u003e0.4...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous pickup adjustment [Ii]\u003c\/td\u003e\n\u003ctd\u003e1.5...10 x Ir, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle, rotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside), 70 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e280 x 327 x 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C operation, -50...85 °C storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the H frame on the incomer or anywhere upstream fault current can reach 70 kA at 380\/415 V -- it is the highest-breaking frame at this amperage. The 4-pole frame adds switched neutral protection, selectable at 0.5 x Ir for a half-protected N\/2 conductor or 1 x Ir for a fully protected neutral -- relevant on TT or TN-S systems carrying unbalanced single-phase loads. Within the 800 A CVS800 frame size, E080H420FM (H class) sits alongside breaking-class siblings at the same amperage -- move up a class if downstream fault studies show higher prospective short-circuit current than 70 kA at 380\/415 V, since the ETS 2.0 long-time setting only trims down to 0.4 x In (320 A) and cannot raise the frame's current rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54076243902747,"sku":"E080H420FM","price":1679.92,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-e080h420fm-cvs800h-moulded-case-circuit-breaker.jpg?v=1790868163","url":"https:\/\/stoklink.com\/products\/schneider-electric-e080h420fm","provider":"Stoklink","version":"1.0","type":"link"}