{"product_id":"schneider-electric-c25r4tm160-compact-nsx250r-mccb","title":"Schneider Electric C25R4TM160 ComPacT NSX250R 4P 160 A 200 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25R4TM160 is a 4-pole ComPacT NSX250R moulded case circuit breaker rated 160 A on a TM-D thermal-magnetic trip unit, with the neutral pole protected at 1 x Ir. Breaking capacity (Icu) reaches 200 kA at 380\/415 V AC and 45 kA at 660\/690 V AC, with a 690 V AC rated operational voltage, for 4-wire distribution boards needing a protected neutral.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC25R4TM160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX250R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Protection Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kA at 220\/240 V AC, 200 kA at 380\/415 V AC, 200 kA at 440 V AC, 80 kA at 500 V AC, 65 kA at 525 V AC, 45 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kA at 220\/240 V AC, 200 kA at 380\/415 V AC, 200 kA at 440 V AC, 80 kA at 500 V AC, 65 kA at 525 V AC, 45 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4th pole trips at 1 x Ir, matching the phase setting, which suits installations where the neutral conductor is sized like the phases and must be protected against overload. Combined with 200 kA Icu at 415 V AC, the C25R4TM160 fits high-fault-current 4-wire feeders; choose a lower-current sibling in the same NSX250R 4P series to size the breaker to the circuit without losing the protected-neutral function, or drop to the NSX250N for an unprotected-neutral board.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229653438747,"sku":"C25R4TM160","price":812.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c25r4tm160.jpg?v=1790868789","url":"https:\/\/stoklink.com\/products\/schneider-electric-c25r4tm160-compact-nsx250r-mccb","provider":"Stoklink","version":"1.0","type":"link"}