{"product_id":"schneider-electric-c25n6tm200-compact-nsx250n-mccb","title":"Schneider Electric C25N6TM200 ComPacT NSX250N 4P 200 A 50 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C25N6TM200 is a 4-pole ComPacT NSX250N moulded case circuit breaker with the neutral pole unprotected (3D), rated 200 A on a TM-D thermal-magnetic trip unit. Breaking capacity (Icu) is 50 kA at 380\/415 V AC, with a 690 V AC rated operational voltage, so it suits 3-phase distribution boards with an unswitched neutral conductor.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC25N6TM200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX250N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D (neutral not protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 380\/415 V AC, 50 kA at 440 V AC, 36 kA at 500 V AC, 35 kA at 525 V AC, 10 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 380\/415 V AC, 50 kA at 440 V AC, 36 kA at 500 V AC, 35 kA at 525 V AC, 10 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...10 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe unprotected neutral (3D) suits a distribution board where the neutral conductor is sized the same as the phases and does not need its own trip threshold, avoiding nuisance tripping on neutral imbalance. The LI trip unit gives an adjustable thermal overload (Ir, 0.7-1 x In) with an adjustable instantaneous short-circuit threshold; choose the C25N6TM200 over a protected-neutral NSX250R or NSX250HB1 variant when the installation does not require a 4th protected pole or a higher breaking capacity than 50 kA at 415 V AC.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229651669275,"sku":"C25N6TM200","price":538.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c25n6tm200.jpg?v=1790868752","url":"https:\/\/stoklink.com\/products\/schneider-electric-c25n6tm200-compact-nsx250n-mccb","provider":"Stoklink","version":"1.0","type":"link"}