{"product_id":"schneider-electric-c16f4tm160d1-nsx160-dc-pv-mccb","title":"Schneider Electric C16F4TM160D1 ComPacT NSX160 DC PV 4P 160 A 10 kA DC TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C16F4TM160D1 is a 4-pole Schneider Electric ComPacT NSX160 DC PV moulded case circuit breaker rated 160 A at 40 °C, built for 1000 V DC photovoltaic circuits with a TM-DC thermal-magnetic trip unit and a DC breaking capacity (Icu) of 10 kA with all four poles connected in series, at a net weight of 2.8 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC16F4TM160D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX160 DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotovoltaic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC, 4 poles in series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (thermal-magnetic, DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A, fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside, front downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 160 A the C16F4TM160D1 covers the higher end of string or combiner-box current in this DC PV frame, sharing the identical 140 x 161 x 86 mm body, 10 kA DC Icu and 1250 A fixed instantaneous pickup with the 125 A variant. The 0.7...1 x In adjustable thermal range lets the setting be dropped below 160 A if the array's actual short-circuit current is lower, without moving to the smaller-frame 125 A unit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eString or sub-array protection on 1000 V DC photovoltaic installations, ahead of the inverter DC input, where the breaker must clear DC fault current rather than only isolate it.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229507096859,"sku":"C16F4TM160D1","price":627.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c16f4tm160d1-nsx160-dc-pv-mccb.jpg?v=1790869631","url":"https:\/\/stoklink.com\/products\/schneider-electric-c16f4tm160d1-nsx160-dc-pv-mccb","provider":"Stoklink","version":"1.0","type":"link"}