{"product_id":"schneider-electric-c160n350fm-compact-ns1600n-mccb","title":"Schneider Electric C160N350FM ComPacT NS1600N 3P 1600 A 50 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C160N350FM is a 3-pole, 1600 A ComPacT NS1600N moulded case circuit breaker rated for a breaking capacity of 50 kA at 380\/415 V AC. It carries a MicroLogic 5.0 electronic trip unit with long-time, short-time and instantaneous (LSI) protection and an operational voltage of 690 V AC, suited for fixed, manually-operated distribution boards up to 1600 A.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC160N350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] Insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Rated service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kA at 220\/240 V AC, 37 kA at 380\/415 V AC, 37 kA at 440 V AC, 30 kA at 500\/525 V AC, 22 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit protection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4...1 x In (adjustable, 9 settings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Isd] Short-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5...10 x Ir (adjustable, 9 settings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode \/ Control type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, manually operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 x 327 x 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe MicroLogic 5.0 trip unit decodes to long-time overload (L), short-time delay (S) and instantaneous (I) protection, giving the C160N350FM adjustable short-time discrimination with downstream breakers in a 3-pole, 1600 A NS1600N frame. Zone selective interlocking is not available on this trip unit, so fault clearance relies on the Isd time-delay setting instead of a ZSI link. Choose this 5.0 (LSI) version over the 2.0 (LI) sibling when short-time coordination is required, or over 6.0 (LSIG) when ground-fault protection is not needed in this circuit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229568766235,"sku":"C160N350FM","price":2775.05,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c160n350fm-compact-ns1600n-mccb.jpg?v=1790868196","url":"https:\/\/stoklink.com\/products\/schneider-electric-c160n350fm-compact-ns1600n-mccb","provider":"Stoklink","version":"1.0","type":"link"}