{"product_id":"schneider-electric-c160h32afm-compact-ns1600h-mccb","title":"Schneider Electric C160H32AFM ComPacT NS1600H 3P 1600 A 70 kA MicroLogic 2.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C160H32AFM is a 3-pole, 1600 A ComPacT NS1600H moulded case circuit breaker rated for 70 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 2.0 A electronic trip unit delivering long-time overload and instantaneous short-circuit protection, and is rated up to 690 V AC for high-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC160H32AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1600 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 65 kA at 440 V AC, 50 kA at 500\/525 V AC, 42 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e37 kA at 220\/240 V AC, 37 kA at 380\/415 V AC, 37 kA at 440 V AC, 30 kA at 500\/525 V AC, 22 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Ii (instantaneous): 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display\u003c\/td\u003e\n\u003ctd\u003eLCD display – Ammeter (RMS current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e210 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe H-frame classification gives the C160H32AFM 70 kA Icu at 380\/415 V AC — choose it over the N-frame version of the same 1600 A frame when prospective short-circuit current at the installation point runs above standard distribution levels. Its MicroLogic 2.0 A trip unit covers long-time overload and instantaneous protection only (LI), with no short-time delay stage — choose a 5.0 (LSI) or 6.0 (LSIG) trip unit from this same frame where selective coordination with downstream breakers is required. The A suffix adds a digital LCD screen with an RMS ammeter, giving it a local current readout without a separate meter. At 210 mm wide on 3 poles, it suits 3-phase-only distribution with no neutral protection; the 4-pole version of the same frame is available where the neutral conductor must be switched and protected.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229561098523,"sku":"C160H32AFM","price":2842.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c160h32afm-compact-ns1600h-mccb.jpg?v=1790868151","url":"https:\/\/stoklink.com\/products\/schneider-electric-c160h32afm-compact-ns1600h-mccb","provider":"Stoklink","version":"1.0","type":"link"}