{"product_id":"schneider-electric-c12n6tm125b-compact-nsxm160n-mccb","title":"Schneider Electric C12N6TM125B ComPacT NSXm160N 4P 125 A 50 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C12N6TM125B is a 4-pole (3D, neutral unprotected) Schneider Electric ComPacT NSXm160N moulded case circuit breaker rated 125 A, with a TM-D thermal-magnetic trip unit and 50 kA breaking capacity (Icu) at 380\/415 V AC. Rated operational voltage (Ue) is 440 V AC. The 108 x 137 x 80 mm frame switches the neutral alongside the three protected phases.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC12N6TM125B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSXm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D, neutral left unprotected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI (long-time overload + instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A, fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, DIN rail or mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside, front downside, compression lug\/busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm with spreaders, 27 mm without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 x 137 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePicking the N-rated C12N6TM125B over the equivalent F-rated 36 kA\/4P\/125 A unit makes sense when the board's prospective fault current exceeds 36 kA — the extra 14 kA of Icu headroom avoids a frame change later if upstream fault levels rise. As a 3D breaker the fourth pole only switches the neutral; it is not thermally or magnetically protected, so neutral overload protection must come from elsewhere in the distribution design if required.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54076466528539,"sku":"C12N6TM125B","price":487.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c12n6tm125b-nsxm160n-mccb.jpg?v=1790869564","url":"https:\/\/stoklink.com\/products\/schneider-electric-c12n6tm125b-compact-nsxm160n-mccb","provider":"Stoklink","version":"1.0","type":"link"}