{"product_id":"schneider-electric-c10n1tm030-nsx100n-mccb","title":"Schneider Electric C10N1TM030 ComPacT NSX100N 1P 30 A 25 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10N1TM030 is a 1P, 30 A ComPacT NSX100N moulded case circuit breaker fitted with a TM-D thermal-magnetic trip unit rated for 25 kA breaking capacity at 240 V AC. It carries a 277 V rated operational voltage and mounts on a fixed backplate, suited to distribution circuits sized to its 30 A nameplate rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10N1TM030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e30 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e25 kA at 220\/240 V AC, 50 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e25 kA at 220\/240 V AC, 50 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003e[Ir] fixed at 1x In; [Ii] fixed 300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N frame sits at the mid tier of the ComPacT NSX100 breaking-capacity ladder (25 kA at 240 V AC), between the F (36 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. The TM-D trip unit on this C10N1TM030 variant has its thermal pickup fixed at 1x In, so the 30 A rating is the circuit's protected current with no field adjustment; choose the adjacent current rating in the same N frame if the protected load differs from 30 A.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229601567003,"sku":"C10N1TM030","price":124.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10n1tm030-nsx100n-mccb.jpg?v=1790868242","url":"https:\/\/stoklink.com\/products\/schneider-electric-c10n1tm030-nsx100n-mccb","provider":"Stoklink","version":"1.0","type":"link"}