{"product_id":"schneider-electric-c10h3ma025-nsx100h-mccb","title":"Schneider Electric C10H3MA025 ComPacT NSX100H 3P 25 A 70 kA MA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10H3MA025 is a ComPacT NSX100H molded case circuit breaker built for motor protection circuits. Configured as 3P, it is rated for 25 A continuous current with a 70 kA breaking capacity (Icu) at 415 V AC, and carries a MA magnetic-only trip unit for short-circuit protection (no integral thermal element, paired with a separate overload relay).\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10H3MA025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 65 kA at 440 V AC, 50 kA at 500 V AC, 35 kA at 525 V AC, 10 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic-only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI (instantaneous short-circuit only, no thermal element)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Isd] short-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, 9 settings, 6-14 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, 9 settings, 6-14 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm x 161 mm x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe C10H3MA025 pairs a magnetic-only MA trip unit with the NSX100H frame (a high breaking-capacity frame), so it provides instantaneous short-circuit protection only (adjustable 6-14 x In) and needs a separate thermal overload relay or motor starter to cover overload protection. That split is standard for motor circuits where a dedicated overload device already exists downstream. Choose a higher-current MA variant if the motor's locked-rotor current exceeds this unit's 25 A setting range; choose the TM-D version of the same frame if a single integrated thermal-magnetic device is preferred instead. It is also rated Yes for isolation duty under EN\/IEC 60947-2, so it can double as the local point of isolation ahead of the motor starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54075185266971,"sku":"C10H3MA025","price":222.36,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10h3ma025-nsx100h-mccb.jpg?v=1790860525","url":"https:\/\/stoklink.com\/products\/schneider-electric-c10h3ma025-nsx100h-mccb","provider":"Stoklink","version":"1.0","type":"link"}