{"product_id":"schneider-electric-c10h32m100-nsx100h-mccb","title":"Schneider Electric C10H32M100 ComPacT NSX100H 3P 100 A 70 kA MicroLogic 2.2 M Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10H32M100 is a ComPacT NSX100H molded case circuit breaker built for motor protection circuits. Configured as 3P, it is rated for 100 A continuous current with a 70 kA breaking capacity (Icu) at 415 V AC, and carries an electronic MicroLogic 2.2 M trip unit with adjustable long-time, short-time and instantaneous (LSoI (long-time, short-time with fixed delay, instantaneous)) motor protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10H32M100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 65 kA at 440 V AC, 50 kA at 500 V AC, 35 kA at 525 V AC, 10 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.2 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLSoI (long-time, short-time with fixed delay, instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, 9 settings, 50-100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[tr] long-time delay adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed per trip class (class 5, 10 or 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Isd] short-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, 9 settings, 5-13 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor tripping class \/ complementary protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 5, 10 or 20; phase unbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm x 161 mm x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe C10H32M100 uses an electronic MicroLogic 2.2 M trip unit on the NSX100H frame (a high breaking-capacity frame), giving adjustable long-time pick-up (50-100 A), a selectable trip class (5, 10 or 20) for the motor's starting profile, and phase-unbalance protection that a fixed thermal-magnetic unit cannot provide. Pick trip class 10 for standard-inertia motors and class 20 for high-inertia loads with longer starting times, since a class that is too fast will nuisance-trip on startup and one that is too slow under-protects the motor winding. The instantaneous pick-up is fixed at 1500 A, so short-circuit response time does not change with the Ir or trip-class settings.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54075183759643,"sku":"C10H32M100","price":315.62,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10h32m100-nsx100h-mccb.jpg?v=1790860500","url":"https:\/\/stoklink.com\/products\/schneider-electric-c10h32m100-nsx100h-mccb","provider":"Stoklink","version":"1.0","type":"link"}