{"product_id":"schneider-electric-bmxmsp0200-x80-pto-module","title":"Schneider Electric BMXMSP0200 Modicon X80 2-Channel PTO Module 24V DC PLC I\/O Module","description":"\u003cp\u003eThe Schneider Electric BMXMSP0200 is a Modicon X80 PTO (pulse train output) module providing 2 pulse-output channels and 4 sink-type discrete inputs at 24 V DC. It connects through two 28-way connectors, draws up to 200 mA at 3.3 V DC, and outputs pulses at up to 200 kHz depending on the receiving circuit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eBMXMSP0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595863998634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePTO module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003e2-wire\/3-wire proximity sensor, 19.2...30 V (IEC 947-5-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e1 pulse output, 2 auxiliary outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003eup to 200 kHz (circuit- and distance-dependent, 0.5...10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e35 mA at 24 V DC (preactuator); 150...200 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eunder 200 microseconds (position\/drive-ready inputs); under 60 microseconds (origin\/proximity inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Between Channels\u003c\/td\u003e\n\u003ctd\u003eNot insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation, Primary-Secondary\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e2 connectors, 28 pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25...70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Characteristic\u003c\/td\u003e\n\u003ctd\u003eHazardous location, Class I Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003eRUN, I\/O fault, ERR, DL, and channel-status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States (US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eMerchant Navy\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eIECEx Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eIEC 61010-2-201\u003c\/li\u003e\n\u003cli\u003eUL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eIEC 61000-6-5\u003c\/li\u003e\n\u003cli\u003eIEC 61850-3\u003c\/li\u003e\n\u003cli\u003eIEC 60079-0\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSpecify the BMXMSP0200 when a Modicon M580 or M340 axis needs open-loop pulse-train positioning without a full servo drive; the pulse output reaches 200 kHz over short cable runs under 0.5 m with the USIC converter, dropping to 100 kHz for a standard 5 m source-input run. Because the two channels are not insulated from each other, keep both pulse channels on signals that share a common reference.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eOpen-loop pulse-train control of stepper or servo drive positioning inputs on Modicon M580 and M340 Programmable Automation Controllers, including installations that extend into Class I Division 2 hazardous locations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54072510349595,"sku":"BMXMSP0200","price":348.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-bmxmsp0200-x80-pto-module.jpg?v=1790804305","url":"https:\/\/stoklink.com\/products\/schneider-electric-bmxmsp0200-x80-pto-module","provider":"Stoklink","version":"1.0","type":"link"}