{"product_id":"schneider-electric-bmxdao1605-discrete-output-100-240vac","title":"Schneider Electric BMXDAO1605 Modicon X80 16 Discrete Triac Outputs 100-240V AC PLC I\/O Module","description":"\u003cp\u003eThe Schneider Electric BMXDAO1605 is a Modicon X80 discrete output module with 16 triac outputs rated 100-240 V AC (85-288 V AC operating range), switching up to 0.6 A per channel. Response time is under 1.011 ms on activation and deactivation, and each output is protected by an external fast-blow fuse.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMXDAO1605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3595863966954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (triac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (85-288 V AC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA at 3.3 V DC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.025-4.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time on Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.011 ms activation and deactivation (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.5 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2830 V AC 50\/60 Hz, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF Reliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 external fuse, fast blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eEN 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BMXDAO1605 switches AC loads up to 0.6 A per channel across 16 triac outputs, for pilot lights, small solenoids, and contactor coils wired directly to 100-240 V AC — not for loads exceeding the 4.8 A total module limit. Its sub-1.011 ms response time is fast enough for sequencing logic that toggles outputs every scan cycle, without the contact wear a relay output module would accumulate at that duty cycle. Choose the relay-output variant in the range instead when the load needs DC switching or dry contacts, since triac outputs only switch AC.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54072505958683,"sku":"BMXDAO1605","price":369.42,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-bmxdao1605-modicon-x80-discrete-output.jpg?v=1790806112","url":"https:\/\/stoklink.com\/products\/schneider-electric-bmxdao1605-discrete-output-100-240vac","provider":"Stoklink","version":"1.0","type":"link"}