{"product_id":"schneider-electric-bmxart0814-x80-8ch-rtd-thermocouple-input","title":"Schneider Electric BMXART0814 Modicon X80 8-Channel Isolated RTD\/Thermocouple Input Module PLC I\/O Module","description":"\u003cp\u003eThe Schneider Electric BMXART0814 is a Modicon X80 analog input module with 8 isolated, low-level channels for RTD and thermocouple temperature sensors, at 15-bit + sign resolution. It supports Cu10, Ni100, Ni1000, Pt100, and Pt1000 RTDs plus B, E, J, K, L, N, R, S, T, U thermocouples, with external cold-junction compensation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMXART0814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3595863966794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog input module, isolated, low level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD (Cu10, Ni100, Ni1000, Pt100, Pt1000), thermocouple (B, E, J, K, L, N, R, S, T, U), mV (±40 to ±1280 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog\/Digital Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigma-delta 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-bit + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Between Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal, by Pt100 probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 dB (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Read Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 ms (thermocouple), 400 ms (RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (RTD\/thermocouple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA at 3.3 V DC, 50 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eEN 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the BMXART0814 over the 4-channel RTD\/thermocouple card when a temperature-monitoring station needs 8 channels in one slot rather than 4 — resolution and sensor-type support (Cu10, Ni100, Ni1000, Pt100, Pt1000 RTDs; B, E, J, K, L, N, R, S, T, U thermocouples) stay the same, but MTBF drops from 1,400,000 h at 4 channels to 900,000 h at 8, and current draw rises to 50 mA at 24 V DC. Each channel still carries its own cold-junction compensation via an external Pt100 probe, so mixing sensor types across channels on the same module is supported. The 40-way, 2-connector wiring layout keeps the 8 channels on the same physical footprint style as the 4-channel card, simplifying panel design when both module sizes appear across a project.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54072509366555,"sku":"BMXART0814","price":720.16,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-bmxart0814-x80-8-ch-rtd-thermocouple-input.jpg?v=1790804197","url":"https:\/\/stoklink.com\/products\/schneider-electric-bmxart0814-x80-8ch-rtd-thermocouple-input","provider":"Stoklink","version":"1.0","type":"link"}