{"product_id":"schneider-electric-blrcs339a407b48n-easylogic-pfc-capacitor","title":"Schneider Electric BLRCS339A407B48N EasyLogic 33.9 kvar 480 V 3-Phase Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS339A407B48N is an EasyLogic standard-duty power factor correction capacitor rated 33.9 kvar at 480 V AC, 50 Hz (40.7 kvar at 60 Hz), built for three-phase networks with network harmonic content at or below 10%. The metallized polypropylene film element is housed in a IP00 can with stud terminals, dimensioned 116 mm diameter by 321 mm high and weighing 4.1 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS339A407B48N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.9 kvar at 480 V, 50 Hz \/ 40.7 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric losses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower losses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 W\/kVAr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to +10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is a standard-duty (SDuty) EasyLogic capacitor, intended for networks with network harmonic content at or below 10% and no significant non-linear loads — where variable frequency drives or large rectifier loads push harmonic content higher, the heavy-duty (HDuty) EasyLogic range with detuned reactors is the correct choice instead. Within the 480 V EasyLogic SDuty line, select this 33.9 kvar unit to match the reactive power deficit measured at the compensation point; oversizing a correction capacitor raises the risk of resonance with upstream reactive elements, so pairing kvar step size to the actual load profile matters more than rounding up to the next sibling rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080598147355,"sku":"BLRCS339A407B48N","price":142.72,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs339a407b48n-easylogic-pfc-capacitor.jpg?v=1790934911","url":"https:\/\/stoklink.com\/products\/schneider-electric-blrcs339a407b48n-easylogic-pfc-capacitor","provider":"Stoklink","version":"1.0","type":"link"}