{"product_id":"schneider-electric-blrch400a480b40-hduty-40kvar-400v","title":"Schneider Electric BLRCH400A480B40 VarPlus Can HDuty 40 kvar 400 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH400A480B40 is a VarPlus Can HDuty power factor correction capacitor rated 40 kvar at 400 V, 50 Hz (48 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a stud terminals in a 136 mm diameter, IP00 enclosure weighing 5.3 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH400A480B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kvar at 400 V, 50 Hz \/ 48 kvar at 400 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 380 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.1 kvar at 50 Hz \/ 43.3 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 415 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.1 kvar at 50 Hz \/ 51.7 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH400A480B40 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 400 V the unit delivers 40 kvar on a 50 Hz network or 48 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 136 mm x 321 mm can and stud terminals keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080610599195,"sku":"BLRCH400A480B40","price":171.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch400a480b40-varplus-can-hduty-capacitor.jpg?v=1790935046","url":"https:\/\/stoklink.com\/products\/schneider-electric-blrch400a480b40-hduty-40kvar-400v","provider":"Stoklink","version":"1.0","type":"link"}