{"product_id":"schneider-electric-atvrd15n4-15kw-regenerative-unit","title":"Schneider Electric ATVRD15N4 Altivar 15 kW Regenerative Unit for ATV320 ATV340 ATV900","description":"\u003cp\u003eThe Schneider Electric ATVRD15N4 is a 15 kW class regenerative unit from the Altivar range, rated for 380-500 V three-phase supply, with 13.5 kW continuous input power and a built-in EMC filter conforming to IEC 61800-3. It returns braking energy from Altivar ATV320, ATV340 and ATV900 drives back to the AC supply instead of dissipating it through a resistor, for heavy braking duty such as material handling and hoisting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATVRD15N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481144225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct \/ Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower module (regenerative unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Drives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Machine ATV320, Altivar Machine ATV340, Altivar Process ATV900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-500 V (-15% \/ +10%), 45-65 Hz, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (DC Bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e456-778 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum DC Bus Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300-880 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (Continuous Input)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5 kW at 380-500 V AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current (Continuous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.8 A at 380 V, 27.9 A at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current (Transient, 60 s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.1 A at 380 V, 36.3 A at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current (Continuous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.9 A at 380 V, 23.2 A at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current (Transient, 60 s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.5 A at 380 V, 29.7 A at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Drop at Rated Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 399 x 235 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10...50 degC without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecUL\u003c\/li\u003e\n\u003cli\u003eIEC 61800-3\u003c\/li\u003e\n\u003cli\u003eIEC 61800-5-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse the ATVRD15N4 in place of a braking resistor when the application returns energy to the line repeatedly rather than dissipating it as heat: hoists, centrifuges and other loads with frequent regenerative braking cycles benefit most, since the unit feeds recovered energy back to the 380-500 V AC supply instead of a resistor bank. It is sized for compatibility with ATV320, ATV340 and ATV900 drives; match its DC bus voltage range of 456-778 V to the connected drive's bus before installing it, and provide clear airflow around its fan-cooled enclosure, since it relies on forced ventilation rather than natural convection to stay within its rated ambient range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038276768027,"sku":"ATVRD15N4","price":1346.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-atvrd15n4-altivar-regenerative-unit.jpg?v=1790302650","url":"https:\/\/stoklink.com\/products\/schneider-electric-atvrd15n4-15kw-regenerative-unit","provider":"Stoklink","version":"1.0","type":"link"}