{"product_id":"schneider-electric-ats490c17y-altivar-soft-starter-170a","title":"Schneider Electric ATS490C17Y Altivar ATS490 170A 208-690V AC 90 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C17Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 170 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 90 kW at 400 V (75 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C17Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 235 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 170 A normal duty, the ATS490C17Y covers motors up to 90 kW at 400 V; size on the heavy-duty rating (140 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 90 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281421083,"sku":"ATS490C17Y","price":2574.36,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c17y-altivar-soft-starter-ats490.jpg?v=1790303186","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats490c17y-altivar-soft-starter-170a","provider":"Stoklink","version":"1.0","type":"link"}