{"product_id":"schneider-electric-ats01n232rt-ats01","title":"ATS01N232RT, ATS01 Series Soft Starter, 15 kW, 32 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N232RT\u003c\/h3\u003e \u003cp\u003e The Schneider ATS01N232RT is a compact three-phase motor soft starter rated for 32 A continuous current and intended for 460–480 V AC supply systems. According to Schneider-authorized datasheets and distributor listings, this model is typically applied on motors up to approximately 20 HP (three-phase at 460–480 V), making it suitable for medium-duty pumps, fans and compressors where controlled torque during acceleration reduces mechanical stress and inrush current. The ATS01N232RT uses a voltage-ramp start method with adjustable start and stop times (1 to 10 seconds) and a selectable starting torque range (approximately 30–80% of direct-on-line torque). The unit includes an internal bypass, an IP20 protection rating, basic discrete control inputs and status outputs, and is designed for straightforward, low‑configuration industrial motor starting where simple, reliable soft start functionality is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 32 A.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Up to ~20 HP (3-phase at 460–480 V).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 460…480 V AC (nominal).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start (adjustable ramp 1–10 s).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated overload protection specified on distributor data (basic motor control and start\/stop functions).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Not specified \/ no fieldbus interfaces listed.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20.\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltage does the ATS01N232RT require?\u003c\/h4\u003e \u003cp\u003eThe ATS01N232RT is specified for 460–480 V AC three-phase supply operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor size can I start with this model?\u003c\/h4\u003e \u003cp\u003eDistributor and datasheet listings indicate suitability for motors up to about 20 HP at 460–480 V (approximate maximum based on rated current 32 A).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust start and stop times on the ATS01N232RT?\u003c\/h4\u003e \u003cp\u003eYes — start and stop ramp times are adjustable, typically from 1 to 10 seconds as documented by Schneider-authorized sources.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N232RT include an internal bypass and motor overload protection?\u003c\/h4\u003e \u003cp\u003eThe unit includes an internal bypass. Distributor data indicate no integrated motor overload protection is provided — external protection is recommended where required.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283862299,"sku":"ATS01N232RT","price":210.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/Schneider_Electric_ATS01N232RT_ATS01_Soft_Starter_15_kW_32_A_380_to_415V_AC.jpg?v=1768545134","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats01n232rt-ats01","provider":"Stoklink","version":"1.0","type":"link"}