{"product_id":"schneider-electric-ats01n222lu-ats01","title":"ATS01N222LU, ATS01 Series Soft Starter, 11 kW, 22 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N222LU\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N222LU is a compact DIN-rail Altistart 01 soft starter rated for 22 A continuous operation and intended for 3-phase supply voltages of 200–240 V AC. It is suitable for motor ratings typically from about 4 kW up to 5.5 kW (approx. 5–7.5 hp) at 200–240 V, making it a practical choice for small to medium machines such as pumps, fans, compressors, conveyor drives and automated doors where simple soft starting is required. The unit uses a voltage-ramp start method with an adjustable start\/stop ramp (commonly 1 to 10 s) and provides an integrated electronic bypass to reduce heat dissipation and audible noise after starting. Physically slim (≈45 mm wide) and DIN-rail mountable, the ATS01N222LU is designed for straightforward installation and basic on-site configuration with a small number of settings and discrete control inputs for start\/stop and boost functions. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 22 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e ~4 kW to 5.5 kW at 200–240 V (approximately 5–7.5 hp)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 200–240 V AC, 3-phase (50\/60 Hz)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start \/ adjustable ramp time (typ. 1–10 s)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection: No (starter provides start control and signalling outputs)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDiscrete Control \/ I\/O:\u003c\/strong\u003e Logic discrete inputs (LI1, LI2, BOOST) and relay \/ open-collector signalling outputs\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (DIN-rail, panel-mountable)\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum continuous current for the ATS01N222LU?\u003c\/h4\u003e \u003cp\u003eThe ATS01N222LU is rated for 22 A continuous (Ie) operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich motor sizes and voltage class does this soft starter support?\u003c\/h4\u003e \u003cp\u003eIt is intended for 3-phase motors on 200–240 V AC supplies, typically around 4 kW up to 5.5 kW (≈5–7.5 hp) depending on application and duty.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N222LU include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — the model includes an integrated electronic bypass to reduce heat and noise after the motor reaches line voltage.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eHow is start\/stop timing configured on this model?\u003c\/h4\u003e \u003cp\u003eStart and stop ramp times are adjustable (commonly configurable in the 1 to 10 second range) using the unit’s simple configuration controls.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283534619,"sku":"ATS01N222LU","price":181.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/Schneider_Electric_ATS01N222LU_ATS01_Soft_Starter_11_kW_22_A_380_to_415V_AC.jpg?v=1768545283","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats01n222lu-ats01","provider":"Stoklink","version":"1.0","type":"link"}