{"product_id":"schneider-electric-ats01n112ft-ats01","title":"ATS01N112FT, ATS01 Series Soft Starter, 5,5 kW, 12 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N112FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N112FT is a compact ATS01-series motor soft starter with a rated operational current of 12 A and a wide supply voltage range (nominally 110…480 V). It is sized for small to medium asynchronous motors — typical in-line motor ratings quoted for this model include approximately 1.5 kW for single-phase 230 V motors, 2.2 kW for three-phase 230 V motors and up to 5.5 kW for three-phase 400 V motors (manufacturer power-range groupings also list 1.1–2 kW at 200–240 V 1‑phase, 2.2–3 kW at 200–240 V 3‑phase and 4–6 kW at 380–440 V 3‑phase). The device uses a voltage-ramp soft start (start with voltage ramp) with adjustable starting time (1 to 5 s) to limit inrush current and reduce mechanical stress during acceleration. The ATS01N112FT includes an internal bypass to reduce heat dissipation once the motor reaches speed and is designed for simple machine applications — pumps, fans and compressors — where basic soft starting and low-configuration operation are required. It is a compact, IP20-protected unit with no integrated motor overload relay, and it accepts common control supply voltages (control supply options include 110–240 V AC and 24 V DC as specified by Schneider Electric). \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 12 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 1.1–2 kW (200–240 V 1‑phase); 2.2–3 kW (200–240 V 3‑phase); 4–6 kW (380–440 V 3‑phase). Manufacturer examples: 1.5 kW (1‑phase 230 V), 2.2 kW (3‑phase 230 V), 5.5 kW (3‑phase 400 V).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110…480 V (nominal supply range)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (start with voltage ramp), adjustable start time 1–5 s\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection (requires external protection)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage:\u003c\/strong\u003e 110–240 V AC and 24 V DC (control supply options)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes does the ATS01N112FT support?\u003c\/h4\u003e \u003cp\u003eThe ATS01N112FT is specified for small to medium motors: manufacturer power-groupings cover roughly 1.1–2 kW (200–240 V single‑phase), 2.2–3 kW (200–240 V three‑phase) and 4–6 kW (380–440 V three‑phase); example ratings cited include 1.5 kW (230 V 1‑ph), 2.2 kW (230 V 3‑ph) and 5.5 kW (400 V 3‑ph).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the supply voltage range for this soft starter?\u003c\/h4\u003e \u003cp\u003eThe unit accepts a wide supply voltage range: nominal 110…480 V (suitable for 110–480 V networks as specified by Schneider Electric).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N112FT include motor overload protection?\u003c\/h4\u003e \u003cp\u003eNo. The ATS01N112FT does not include integrated motor overload protection; an external overload or motor protector must be used where required.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust starting behavior (time\/torque)?\u003c\/h4\u003e \u003cp\u003eYes. The starter uses a voltage-ramp start with adjustable starting time (adjustable from 1 to 5 seconds) to tailor acceleration and limit inrush current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs there a bypass after starting to reduce heat?\u003c\/h4\u003e \u003cp\u003eYes. The ATS01N112FT includes an internal bypass to reduce dissipation and noise after the motor reaches running speed.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283043099,"sku":"ATS01N112FT","price":105.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/Schneider_Electric_ATS01N112FT_ATS01_Soft_Starter_5_5_kW_12_A_230_to_400V_AC.jpg?v=1768545645","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats01n112ft-ats01","provider":"Stoklink","version":"1.0","type":"link"}