{"product_id":"schneider-electric-ats01n109ft-ats01","title":"ATS01N109FT, ATS01 Series Soft Starter, 4 kW, 9 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N109FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N109FT is a compact Altistart 01 soft starter rated for 9 A nominal operational current, designed for simple industrial motor starting tasks. It accepts a wide supply voltage range from 110 V to 480 V AC and is suitable for inline three-phase motor powers up to approximately 1.5 kW at 230 V and 4 kW at 400 V (motor power ratings depend on wiring and voltage). The unit is DIN-rail or panel mountable (45 mm width), includes an internal bypass contactor to reduce heat dissipation during run, and provides adjustable starting time and torque suppression (starting torque typically adjustable in the 30–80% range). Built for basic motor control use, the ATS01N109FT is a practical choice for small conveyors, pumps, fans, compressors and other simple motor-driven machines where space is limited and a straightforward motor soft starter is required. Confirmed environmental and mechanical specs include IP20 protection, -10 °C to 40 °C operation without derating (with derating above 40 °C), and compliance with EN\/IEC 60947-4-2. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 9 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e up to ~1.5 kW at 230 V (inline); up to ~4 kW at 400 V (inline)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110–480 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e adjustable voltage ramp \/ torque suppression (starting torque adjustable ~30–80%)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass contactor)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e basic functions provided via soft start control (no integrated overload protection confirmed)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e — (no communication interface confirmed)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS01N109FT?\u003c\/h4\u003e \u003cp\u003eThe ATS01N109FT is rated for 9 A nominal operational current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS01N109FT support?\u003c\/h4\u003e \u003cp\u003eIt supports a wide supply voltage range from 110 V to 480 V AC (50–60 Hz).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N109FT include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes. The unit includes an integrated internal bypass contactor to reduce heat dissipation during motor run.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes and applications is this model suitable for?\u003c\/h4\u003e \u003cp\u003eIt is suitable for small motor-driven machines: roughly up to 1.5 kW at 230 V and up to 4 kW at 400 V (inline). Typical uses include pumps, fans, conveyors, compressors and other simple industrial loads.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat are the operating temperature limits and derating requirements?\u003c\/h4\u003e \u003cp\u003eRated for operation from -10 °C to 40 °C without derating; above 40 °C the current must be derated as specified by Schneider Electric (consult product documentation for exact derating curve).\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230282846491,"sku":"ATS01N109FT","price":93.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/Schneider_Electric_ATS01N109FT_ATS01_Soft_Starter_4_kW_9_A_230_to_400V_AC.jpg?v=1768545684","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats01n109ft-ats01","provider":"Stoklink","version":"1.0","type":"link"}