{"product_id":"schneider-electric-ats01n106ft-ats01","title":"ATS01N106FT, ATS01 Series Soft Starter, 2,2 kW, 6 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N106FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N106FT is an Altistart 01 soft starter rated for 6 A nominal current and designed for wide-voltage installations. It supports a supply voltage range from 110 V up to 480 V AC, making it suitable for both low-voltage single-phase and three-phase systems commonly found in industrial control panels. Typical motor compatibility includes small asynchronous motors — documented examples are 0.75 kW at 230 V and up to 2.2 kW at 400 V — which makes the unit appropriate for light-duty pumps, fans, conveyors and compressors on simple machines. The ATS01N106FT uses a voltage-ramp start method to limit inrush current and reduce mechanical stress during acceleration, includes an internal bypass contactor to reduce heat losses after starting, and is supplied in an IP20 enclosure for panel mounting. This model does not include integrated motor overload protection or advanced communications; it is targeted at applications requiring a compact, easy-to-configure motor soft starter for basic industrial motor starting and to extend mechanical and electrical equipment life. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 6 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Example: 0.75 kW at 230 V; up to 2.2 kW at 400 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110…480 V AC (wide range)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (soft start)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass contactor)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (panel mounting)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eUtilisation Category:\u003c\/strong\u003e AC-53B (EN\/IEC 60947-4-2)\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat voltage range does the ATS01N106FT support?\u003c\/h4\u003e \u003cp\u003eThe ATS01N106FT supports a wide supply voltage range from 110 V to 480 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can this soft starter handle?\u003c\/h4\u003e \u003cp\u003eDocumented examples include 0.75 kW at 230 V and up to 2.2 kW at 400 V; it is intended for small motors on simple machines.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N106FT include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — an internal bypass contactor is provided to reduce dissipation after the motor has started.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes this model provide built-in motor overload protection or communications?\u003c\/h4\u003e \u003cp\u003eNo. The ATS01N106FT does not include integrated motor overload protection or communication interfaces; external protection and monitoring are required if needed.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230282617115,"sku":"ATS01N106FT","price":89.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/Schneider_Electric_ATS01N106FT_ATS01_Soft_Starter_2_2_kW_6_A_230_to_400V_AC.jpg?v=1768545717","url":"https:\/\/stoklink.com\/products\/schneider-electric-ats01n106ft-ats01","provider":"Stoklink","version":"1.0","type":"link"}