{"product_id":"schneider-electric-ath230u30n4-vfd-3kw-380-500v-3ph","title":"Schneider Electric ATH230U30N4 Altivar HVAC ATH230 3 kW 380-500 V 3-Phase IP20 Variable Frequency Drive","description":"\u003cp\u003eThe Schneider Electric ATH230U30N4 is a 3 kW variable frequency drive from the Altivar HVAC ATH200 range, built for HVAC OEM pump, fan, and compressor panels. It accepts a 380-500 V 3-phase supply, delivers a 7.1 A nominal output current, and mounts in IP20 enclosures with an integrated Class C2 EMC filter and native Safe Torque Off (STO) safety.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATH230U30N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar HVAC ATH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATH230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606487882152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-500 V (-15% \/ +10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kW (3.0 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3 kVA at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-16 kHz adjustable (4 kHz nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTO (Safe Torque Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), PL e (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass C2 EMC filter integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, BACnet MS\/TP (BACnet\/IP via optional module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProspective Line Isc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 158 x 184 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume of Cooling Air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.3 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eIEC 61800-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 61800-3\u003c\/li\u003e\n\u003cli\u003eUL 508C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSize the ATH230U30N4 to the driven motor's nameplate current, not the drive's frame rating: its 7.1 A nominal output current at 380-500 V sets the ceiling for the connected pump, fan, or compressor motor. Within the ATH230 line, the 380-500 V 3-phase variant applies where the panel's incoming 3-phase supply matches that band — pick the sibling with a different current or supply rating if the OEM panel's motor or incoming feed differs. The integrated STO input lets the drive sit inside a safety circuit (SIL 3 \/ PL e) without an external contactor to remove torque, and the native Modbus and BACnet MS\/TP ports let a building automation system read status and write speed setpoints directly, without a protocol gateway.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe 3-phase, 380-500 V rating targets HVAC OEM panels that run asynchronous or synchronous pump, fan, and compressor motors up to 3 kW. Native BACnet MS\/TP and Modbus serial ports let it report status and accept speed setpoints from a building management system without a separate gateway.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038262776091,"sku":"ATH230U30N4","price":499.62,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ath230u30n4-altivar-hvac-ath230-vfd.jpg?v=1790301247","url":"https:\/\/stoklink.com\/products\/schneider-electric-ath230u30n4-vfd-3kw-380-500v-3ph","provider":"Stoklink","version":"1.0","type":"link"}