{"product_id":"schneider-electric-a9mem1571-powertag-energy-p63-top-mounted","title":"Schneider Electric A9MEM1571 PowerTag Energy P63 3P+N 63 A Top Mounted Wireless Energy Sensor","description":"\u003cp\u003eThe Schneider Electric A9MEM1571 PowerTag Energy P63 is a 3P+N wireless energy sensor rated 63 A maximum current (10 A base current), top of the breaker only. Its PhaseNeutral form factor matches the narrower 9 mm Ph\/N and 18 mm Ph\/Ph pitch of Acti9 and Multi9 3P+N devices and clips on above the breaker only. It reports active energy, active power, current, voltage and power factor to IEC 61557-12 Class 1 accuracy over a 2.4 GHz IEEE 802.15.4 radio link to a PowerTag-compatible concentrator.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA9MEM1571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerTag P63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhaseNeutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum current (Imax)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic current (Ib)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSaturation current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1 current, active power, active energy, power factor; Class 0.5 voltage (IEC 61557-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured values\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive energy, active power, current, voltage, power factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop of the breaker only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWireless protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4-2.4835 GHz radio, IEEE 802.15.4, 10 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC phase-to-neutral \/ 380-415 V AC phase-to-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax power consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible gateways\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure Panel Server Entry, EcoStruxure Panel Server Universal, EcoStruxure Panel Server Advanced, Wiser hub generation 2, Acti9 Smartlink SI B, Acti9 Smartlink SI D, Acti9 PowerTag Link, Acti9 PowerTag Link HD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible device ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActi9 and Multi9 3P+N PhaseNeutral devices with 9 mm Ph\/N and 18 mm Ph\/Ph pitch (N40 Vigi, C40 Vigi, iDPN, iC40, N40, iCV40, C40, DT40), rated 63 A or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite (RAL 9003)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV Marine\u003c\/li\u003e\n\u003cli\u003eIEC 61557-12\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1\u003c\/li\u003e\n\u003cli\u003eIEC 61010-2-030\u003c\/li\u003e\n\u003cli\u003eIEC 61326-1\u003c\/li\u003e\n\u003cli\u003eETSI EN 300 328\u003c\/li\u003e\n\u003cli\u003eETSI EN 301 489-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the A9MEM1571 instead of the Flex A9MEM1570 when the 3P+N breaker is a standard Acti9 or Multi9 device with the fixed 9 mm\/18 mm PhaseNeutral pitch and the panel has clearance above it -- the PhaseNeutral clip avoids the extra wiring step the Flex lead requires. For the same breaker mounted from below, use the A9MEM1572.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080678494491,"sku":"A9MEM1571","price":177.72,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-a9mem1571-powertag-p63-energy-sensor.jpg?v=1790935491","url":"https:\/\/stoklink.com\/products\/schneider-electric-a9mem1571-powertag-energy-p63-top-mounted","provider":"Stoklink","version":"1.0","type":"link"}