{"product_id":"abb-2csg152435r1202-elr96pf","title":"ABB 2CSG152435R1202 ELR96PF Type A 110-400V AC Residual Current Monitor Relay Monitoring Relay","description":"\u003cp\u003eThe ABB 2CSG152435R1202 ELR96PF is a panel-mount residual current monitor with two changeover contacts, a built-in frequency filter, and a 60% pre-alarm threshold, detecting earth-fault current from 30 mA to 30 A on 110-400 V AC circuits at 50 or 60 Hz. It gives an early warning stage before the main threshold trips a downstream MCB or MCCB.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSG152435R1202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitors, RCMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eELR96PF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542734420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor AC-current system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA | 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Contacts (CO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 5 s | Min 0 s adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith frequency filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePre-Alarm Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Ur)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115-230-400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Control Supply Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-400 V at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 W total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e386 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60947-2 Annex M\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ELR96PF shares the frequency filter and 60% pre-alarm of the DC-capable variant in the same range but keeps the control supply AC-only at 110-400 V, 50 or 60 Hz, which keeps its weight down to 386 g versus the DC-capable unit's 454 g. Specify it on AC-fed panels where filtering is needed to avoid nuisance trips from non-fundamental-frequency fault currents but a DC auxiliary input is not required. Like the other two-contact ELR variants, the pre-alarm contact can flag an approaching fault to a PLC or BMS before the second contact trips the breaker.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229384773915,"sku":"2CSG152435R1202","price":626.34,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csg152435r1202-elr96pf-residual-current-monitor.jpg?v=1790959308","url":"https:\/\/stoklink.com\/products\/abb-2csg152435r1202-elr96pf","provider":"Stoklink","version":"1.0","type":"link"}