{"product_id":"abb-2csf204003r3250-fh204-ac-25-0-3-4p-25a-rccb","title":"ABB 2CSF204003R3250 FH204 AC-25\/0.3 4P 25A 300mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.3 (SKU: 2CSF204003R3250) is a 4-pole residual current circuit breaker (RCCB) rated at 25 A with a 300 mA trip sensitivity, designed for reliable earth-fault and personal protection in industrial and commercial installations. Part of the ABB FH200 series, this DIN-rail mounted device provides Type AC protection — detecting sinusoidal alternating residual currents — making it suitable for a wide range of standard electrical distribution applications. Compact at 70 mm × 85 mm × 69 mm and weighing just 380 g, the FH204 AC-25\/0.3 fits easily into standard control panels and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-25\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204003R3250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Trip Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC (sinusoidal alternating residual current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European standard for residual current circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-fault protection in residential distribution boards and commercial panels\u003c\/li\u003e\n\u003cli\u003ePersonal protection against indirect contact in 3-phase + neutral (4-wire) systems\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring DIN-rail mounted residual current protection\u003c\/li\u003e\n\u003cli\u003eSupplementary protection alongside MCBs in building services and facility management\u003c\/li\u003e\n\u003cli\u003eStandard AC sinusoidal leakage current detection in HVAC, lighting, and general power circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993982747,"sku":"2CSF204003R3250","price":34.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204003r3250-fh204-ac-25-0-3-current-circuit-breaker_3a2c909d-f371-48a8-9c04-2563200e10f1.webp?v=1777162802","url":"https:\/\/stoklink.com\/products\/abb-2csf204003r3250-fh204-ac-25-0-3-4p-25a-rccb","provider":"Stoklink","version":"1.0","type":"link"}