{"product_id":"abb-2cds653061r0204-bms613c20-3p-20a-6ka-mcb","title":"ABB 2CDS653061R0204 BMS613C20 3P 20A 6kA 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS613C20 miniature circuit breaker (SKU 2CDS653061R0204) is a 3-pole, 20 A, C-curve MCB from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 6 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial installations, the BMS613C20 delivers consistent performance in compact DIN-rail assemblies with a power dissipation of just 2.5 W per pole.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS613C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS653061R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779050524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General standard for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e German electrical engineering certification (Verband der Elektrotechnik)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB scheme international safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCA:\u003c\/strong\u003e Certified component approval for circuit protection devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking per applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e EU Directive 2011\/65\/EU — Restriction of Hazardous Substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU Regulation (EC) No 1907\/2006 — Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Directive 2012\/19\/EU — Waste Electrical and Electronic Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of final circuits in commercial buildings, light industry, and infrastructure\u003c\/li\u003e\n\u003cli\u003eControl panel wiring protection for machinery and automation systems\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection in DIN-rail-mounted switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eMotor feeder protection for small three-phase loads (C-curve characteristic)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229388575003,"sku":"2CDS653061R0204","price":16.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds653061r0204-bms613c20-abb-2cds653061r0204-bms613c20_62966ff6-5bfb-4b4b-9b32-c2d1f9de1157.webp?v=1777394303","url":"https:\/\/stoklink.com\/products\/abb-2cds653061r0204-bms613c20-3p-20a-6ka-mcb","provider":"Stoklink","version":"1.0","type":"link"}