{"product_id":"abb-2cds384001r0634-s304p-c63","title":"ABB 2CDS384001R0634 S304P-C63 4P 63A 15kA DIN Rail Miniature Circuit Breaker (MCB)","description":"\u003cp\u003eThe ABB 2CDS384001R0634 is an S304P-C63 miniature circuit breaker for industrial DIN-rail installations rated 63 A across four poles with a C-curve trip characteristic. It carries a 15 kA breaking capacity under IEC 60898-1 and is additionally tested to IEC 60947-2, where it reaches 25 kA at 400 V AC, giving installers a wide margin against short-circuit fault currents on four-wire industrial branch circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No\u003c\/td\u003e\n\u003ctd\u003eS304P-C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e2CDS384001R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS300P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC (IEC 60898-1 \/ IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu, IEC 60947-2)\u003c\/td\u003e\n\u003ctd\u003e25 kA at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity (Icn, IEC 60898-1)\u003c\/td\u003e\n\u003ctd\u003e15 kA at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating (UL 1077)\u003c\/td\u003e\n\u003ctd\u003e10 kA at 480Y\/277 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20, IP40 with cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, 0.75-35 mm² rigid, 0.75-25 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail TH35, any position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e70 mm (4 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.512 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4016779075954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degrees C operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC\/EN 60898-1\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\n\u003cli\u003eUL 1077\u003c\/li\u003e\n\u003cli\u003eCSA 22.2 No. 235\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe C-curve trip setting on the 2CDS384001R0634 suits mixed resistive and inductive branch circuits, such as lighting panels and small motor feeders, with instantaneous tripping typically between 5 and 10 times In. Its 4-pole construction switches and protects all four conductors, which matters where the neutral must also be isolated on 3-phase-plus-neutral or 4-wire systems. The IEC 60947-2 Icu of 25 kA at 400 V AC gives more short-circuit margin than the IEC 60898-1 Icn of 15 kA, so the lower figure is the conservative one to check against upstream fault levels. Circuits with resistive-only loads and lower inrush are better served by a B-curve variant in the same S300P frame, while loads with higher starting currents call for a D-curve version.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229361213723,"sku":"2CDS384001R0634","price":233.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds384001r0634-s304p-c63-mcb.png?v=1790958528","url":"https:\/\/stoklink.com\/products\/abb-2cds384001r0634-s304p-c63","provider":"Stoklink","version":"1.0","type":"link"}