{"product_id":"abb-2cds272001r0254-s202m-c25-2p-25a-mcb","title":"ABB 2CDS272001R0254 S202M-C25 2P 25A 10kA C-Curve 230\/400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB S202M-C25 miniature circuit breaker (SKU: 2CDS272001R0254) is a high-performance 2-pole MCB from the S200M series, rated at 25A with a C-curve trip characteristic and a breaking capacity of 10kA at 230\/400V AC. Designed for residential, commercial, and industrial control panel applications, the S202M-C25 delivers reliable overcurrent and short-circuit protection in a compact 35mm DIN rail-mount form factor weighing just 0.23kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS202M-C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS272001R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779550321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for household and similar miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60898-1:\u003c\/strong\u003e European harmonised standard for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898:\u003c\/strong\u003e General MCB standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898:\u003c\/strong\u003e Overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1400:\u003c\/strong\u003e Extended IEC MCB standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2440:\u003c\/strong\u003e Extended low-voltage switchgear compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60898:\u003c\/strong\u003e European MCB standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European low-voltage circuit breaker standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, upgraded and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e Insulation coordination within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1077:\u003c\/strong\u003e Supplementary protectors for use in electrical equipment (UL listed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring compact 2-pole MCB protection\u003c\/li\u003e\n\u003cli\u003eProtection of motors, lighting circuits, and general electrical installations\u003c\/li\u003e\n\u003cli\u003eDIN rail assembly in automation cabinets and switchgear enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the breaking capacity of the ABB S202M-C25?\u003c\/strong\u003e The S202M-C25 has a breaking capacity (Icu) of 10kA at 230\/400V AC, making it suitable for installations with high prospective short-circuit currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the C-curve trip characteristic mean?\u003c\/strong\u003e A C-curve MCB trips magnetically at 5–10× the rated current, making it ideal for loads with moderate inrush currents such as lighting, heating, and small motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the ABB 2CDS272001R0254 DIN rail mountable?\u003c\/strong\u003e Yes, the S202M-C25 is designed for standard 35mm DIN rail mounting and fits standard distribution boards and control panel enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat certifications does the S202M-C25 hold?\u003c\/strong\u003e It is certified to IEC\/EN 60898-1, IEC\/EN 60947-2, UL 1077, CSA, CE, UKCA, RoHS, REACH, and WEEE, among others.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229219033371,"sku":"2CDS272001R0254","price":22.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds272001r0254-s202m-c25-miniature-circuit-breaker_133a1831-9006-4a00-b111-f62377e1ef6a.webp?v=1777161973","url":"https:\/\/stoklink.com\/products\/abb-2cds272001r0254-s202m-c25-2p-25a-mcb","provider":"Stoklink","version":"1.0","type":"link"}