{"product_id":"abb-2cds272001r0064-s202m-c6-2p-6a-mcb","title":"ABB 2CDS272001R0064 S202M-C6 2P 6A 10kA Curve-C Miniature Circuit Breaker (MCB)","description":"\u003cp\u003eThe ABB S202M-C6 (SKU: 2CDS272001R0064) is a 2-pole 6A C-curve miniature circuit breaker (MCB) from the high-performance S200M series, engineered for demanding industrial and commercial electrical installations. Delivering a breaking capacity of 10kA at 230V AC under IEC\/EN 60898-1, the S202M-C6 provides robust overcurrent and short-circuit protection for control panels, distribution boards, and building services applications. With compact DIN-rail dimensions of 35mm × 88mm × 69mm and a weight of just 0.224kg, this MCB is optimised for space-efficient panel design.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS202M-C6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS272001R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779550260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA @ 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.224 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for household and similar installations MCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60898-1:\u003c\/strong\u003e European harmonised standard for MCBs in residential and commercial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898:\u003c\/strong\u003e Combined IEC and EN compliance for circuit-breaker performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN60898:\u003c\/strong\u003e Verified compliance with the international\/European MCB performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1400:\u003c\/strong\u003e Extended IEC 60898-1 test compliance variant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2440:\u003c\/strong\u003e Extended IEC 60947-2 test compliance variant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for mechanical and climatic robustness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60898:\u003c\/strong\u003e European standard for overcurrent protection devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European low-voltage switchgear standard for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN60898:\u003c\/strong\u003e EN circuit breaker performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN60947:\u003c\/strong\u003e EN low-voltage switchgear and controlgear general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemicals regulation compliance (SVHC substances)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU safety and performance directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of motor branch circuits with inrush tolerance (C-curve) in automation systems\u003c\/li\u003e\n\u003cli\u003eCommercial building services: HVAC controls, lighting circuits, and power distribution\u003c\/li\u003e\n\u003cli\u003eMachine building and OEM panel construction requiring high breaking capacity in compact format\u003c\/li\u003e\n\u003cli\u003eFeeder protection in sub-distribution boards within manufacturing facilities\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the C-curve designation mean on the S202M-C6?\u003c\/strong\u003e\u003cbr\u003eThe C-curve (trip curve C) means the MCB trips instantaneously at 5–10× the rated current (30–60A for a 6A device). This makes the ABB S202M-C6 ideal for loads with moderate inrush currents such as small motors, transformers, and fluorescent lighting circuits.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the breaking capacity of the ABB S202M-C6?\u003c\/strong\u003e\u003cbr\u003eThe S202M-C6 has a rated breaking capacity (Icu) of 10kA at 230V AC per IEC\/EN 60898-1, making it suitable for installations with high prospective short-circuit currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the S202M-C6 DIN rail mountable?\u003c\/strong\u003e\u003cbr\u003eYes. The ABB S202M-C6 mounts on standard 35mm DIN rail and occupies a width of 35mm, equivalent to 2 module widths in a standard distribution enclosure.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229219590427,"sku":"2CDS272001R0064","price":27.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds272001r0064-s202m-c6-circuit-breaker-mcb_070d3325-8472-421e-9f41-7d3325d717ea.webp?v=1777161952","url":"https:\/\/stoklink.com\/products\/abb-2cds272001r0064-s202m-c6-2p-6a-mcb","provider":"Stoklink","version":"1.0","type":"link"}