{"product_id":"abb-2cds254001r0014-s204-c1-4p-1a-6ka-mcb","title":"ABB 2CDS254001R0014 S204-C1 4P 1A 6kA C-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB S204-C1 (SKU: 2CDS254001R0014) is a 4-pole miniature circuit breaker from the S200 series, rated at 1 A with a C-curve trip characteristic and a breaking capacity of 6 kA at 230\/400 V AC. Designed for DIN-rail mounting in industrial and commercial control panels, the S204-C1 delivers reliable overcurrent and short-circuit protection across all four poles simultaneously, making it the ideal choice for sensitive low-current circuits in automation and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS204-C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS254001R0014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779529129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.448 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898-1:\u003c\/strong\u003e International and European standard for household and similar circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e IEC standard for circuit-breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60898-1:\u003c\/strong\u003e European harmonised standard for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e Industrial low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e IEC standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1077:\u003c\/strong\u003e UL standard for supplementary protectors for use in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General IEC standard series for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General IEC standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets all applicable Great Britain regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection for low-current 1 A circuits in industrial control panels\u003c\/li\u003e\n\u003cli\u003eProtection of instrumentation, PLC input\/output modules, and sensitive electronic loads\u003c\/li\u003e\n\u003cli\u003eDistribution board protection in commercial buildings and light industrial facilities\u003c\/li\u003e\n\u003cli\u003eFour-pole isolation providing simultaneous disconnection of all live conductors in 3-phase + neutral systems\u003c\/li\u003e\n\u003cli\u003eControl panel sub-circuit protection in automation, HVAC, and building management systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat does the C-curve trip characteristic mean for the S204-C1?\u003c\/h3\u003e\u003cp\u003eThe C-curve means the breaker will trip instantaneously at 5–10 times the rated current (5–10 A). This is suitable for general loads with moderate inrush currents, such as resistive loads, lighting circuits, and control transformers.\u003c\/p\u003e\u003ch3\u003eIs the ABB S204-C1 suitable for 3-phase systems?\u003c\/h3\u003e\u003cp\u003eYes. With 4 poles rated at 400 V AC, the S204-C1 is designed for use in 3-phase + neutral (TN-S) systems, providing simultaneous protection and isolation across all four conductors.\u003c\/p\u003e\u003ch3\u003eWhat DIN-rail width does the S204-C1 occupy?\u003c\/h3\u003e\u003cp\u003eThe S204-C1 has a width of 88 mm, which corresponds to 4 module widths (4 × 18 mm) on a standard EN 60715 DIN rail — one module per pole.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229213331739,"sku":"2CDS254001R0014","price":40.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds254001r0014-s204-c1-miniature-circuit-breaker_995b790b-7b75-4789-b81c-f9dbfb8297be.webp?v=1777161699","url":"https:\/\/stoklink.com\/products\/abb-2cds254001r0014-s204-c1-4p-1a-6ka-mcb","provider":"Stoklink","version":"1.0","type":"link"}