{"product_id":"abb-2cds252001r0324-s202-c32-2p-32a-6ka-mcb","title":"ABB 2CDS252001R0324 S202-C32 2P 32A 6kA Curve-C DIN-Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB S202-C32 miniature circuit breaker (MCB), SKU 2CDS252001R0324, is a 2-pole, 32A, 6 kA breaking capacity device from the proven S200 series, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. Featuring Curve-C tripping characteristics and rated at 230\/400 V AC, the S202-C32 mounts directly onto standard DIN rail and delivers consistent protection performance to IEC\/EN 60898-1 and IEC\/EN 60947-2 standards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS202-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS252001R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779466202\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898-1:\u003c\/strong\u003e International\/European standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e International\/European standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e IEC standard for household and similar overcurrent protection circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60898-1:\u003c\/strong\u003e European harmonised standard for overcurrent protection circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers (industrial rating)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1400:\u003c\/strong\u003e Extended IEC standard reference for MCB performance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2440:\u003c\/strong\u003e Extended IEC standard reference for industrial circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard (climatic and mechanical robustness)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European standard for low-voltage industrial circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for end-of-life treatment of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 1077:\u003c\/strong\u003e UL standard for supplementary protectors for use in electrical equipment (North America)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval for North American market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machinery protection circuits\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive and inductive loads (motors, transformers, lighting) requiring Curve-C characteristics\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounted distribution assemblies in switchgear enclosures\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in automation and control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat does the \"C\" in S202-C32 mean?\u003c\/strong\u003e The \"C\" denotes the tripping curve, which triggers between 5× and 10× the rated current. Curve-C is suitable for inductive and mixed loads such as motors, transformers, and fluorescent lighting where moderate inrush currents are expected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the breaking capacity of the ABB S202-C32?\u003c\/strong\u003e The S202-C32 has a rated breaking capacity (Icu) of 6 kA at 230\/400 V AC, suitable for standard distribution networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow many poles does the S202-C32 have?\u003c\/strong\u003e It is a 2-pole (2P) device, protecting both live and neutral conductors simultaneously — ideal for single-phase circuits in 230\/400 V AC systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs the ABB S202-C32 DIN-rail compatible?\u003c\/strong\u003e Yes, the S202-C32 is designed for standard 35 mm DIN-rail mounting as per EN 60715.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat certifications does the S202-C32 hold?\u003c\/strong\u003e It carries CE, UKCA, UL 1077, CSA, IEC\/EN 60898-1, IEC\/EN 60947-2, RoHS, REACH, and WEEE compliance, making it suitable for global deployments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229206974747,"sku":"2CDS252001R0324","price":21.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds252001r0324-s202-c32-miniature-circuit-breaker_dd686e4c-c984-42f4-9a4b-bb5df6154b04.webp?v=1777161502","url":"https:\/\/stoklink.com\/products\/abb-2cds252001r0324-s202-c32-2p-32a-6ka-mcb","provider":"Stoklink","version":"1.0","type":"link"}