{"product_id":"abb-2cds251001r0325-s201-b32-1p-32a-mcb","title":"ABB 2CDS251001R0325 S201-B32 1P 32A 6kA B-Curve DIN-Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB S201-B32 miniature circuit breaker (SKU: 2CDS251001R0325) is a 1-pole, 32 A, B-curve MCB from the S200 series, rated at 230\/400 V AC with a breaking capacity of 6 kA per IEC\/EN 60898-1. Designed for DIN-rail mounting in residential, commercial, and light industrial distribution boards, the S201-B32 provides reliable overcurrent and short-circuit protection with a compact 17.5 mm wide profile.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS201-B32\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS251001R0325\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS201\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779465304\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60898-1:\u003c\/strong\u003e International and European standard for household and similar installations MCBs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e International and European standard for low-voltage switchgear circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e IEC standard for overcurrent protection of household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60898-1:\u003c\/strong\u003e European harmonised standard for miniature circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European standard for low-voltage switchgear and controlgear circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1230:\u003c\/strong\u003e Supplementary IEC standard designation for MCB applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for durability and reliability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 1077:\u003c\/strong\u003e UL standard for supplementary protectors for use in electrical equipment (North America)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval for use in North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — complies with applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — complies with applicable UK regulations post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU chemical safety regulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building final circuit protection up to 32 A\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machine wiring\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive and slightly inductive loads (B-curve: trips at 3–5× In)\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounted consumer unit and sub-board installations\u003c\/li\u003e\n  \u003cli\u003eFeeder circuit protection in automation and control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"B\" curve mean on the S201-B32?\u003c\/strong\u003e\u003cbr\u003eThe B trip curve means the breaker trips instantaneously at 3–5 times the rated current (3–5× 32 A = 96–160 A). This is ideal for resistive loads such as lighting circuits, heating elements, and cable protection where low inrush currents are expected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ABB S201-B32 compatible with ABB auxiliary contacts and residual current blocks?\u003c\/strong\u003e\u003cbr\u003eYes. The S200 series is designed to accept a wide range of ABB accessories including auxiliary contacts, shunt trips, undervoltage releases, and residual current blocks (RC2xx series), enabling flexible system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the S201-B32 be used in a 400 V three-phase system?\u003c\/strong\u003e\u003cbr\u003eAs a 1-pole breaker, the S201-B32 protects a single phase conductor. It is rated at 230\/400 V AC, making it suitable for use within a 400 V TN or TT three-phase system to protect individual phase conductors.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229192556827,"sku":"2CDS251001R0325","price":5.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds251001r0325-s201-b32-miniature-circuit-breaker_225c0b0b-d1cf-40b2-8be9-cc9314fc394e.webp?v=1777161393","url":"https:\/\/stoklink.com\/products\/abb-2cds251001r0325-s201-b32-1p-32a-mcb","provider":"Stoklink","version":"1.0","type":"link"}