{"product_id":"abb-1sfl617001r7011-af580-30-11-70-800a-contactor","title":"ABB 1SFL617001R7011 AF580-30-11-70 3-Pole 800A 1000V AC-1 315kW Coil 100-250V AC\/DC Power Contactor","description":"\u003cp\u003eThe ABB AF580-30-11-70 power contactor (SKU 1SFL617001R7011) is a heavy-duty 3-pole AC switching contactor rated at 800 A (AC-1) and 1000 V IEC, delivering 315 kW at 400 V AC (AC-3). Designed for demanding industrial automation and control panel applications, the AF580-30-11-70 features a wide-range coil accepting 100–250 V AC\/DC at 50\/60 Hz, minimising the need for multiple spare variants across global installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF580-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL617001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF580\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500217696\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower contactor, AC switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current UL General Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 \/ 400 V IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL \/ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC (50\/60 Hz) \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL listed for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for South Korean market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine and offshore\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków (Polish Register of Shipping) approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessment of the ability to repair, reuse, and recycle products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-69:\u003c\/strong\u003e Supplementary standard for switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — substances of very high concern compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-power motor switching and control in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eControl panel assembly for pumps, compressors, fans, and large drives\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical distribution switchboards (DNV, ABS, LR, BV, RINA, CCS, PRS approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding services — HVAC plant rooms requiring heavy-duty switching\u003c\/li\u003e\n  \u003cli\u003eProcess industry installations requiring IEC 60947-4 compliant contactors\u003c\/li\u003e\n  \u003cli\u003eGlobal OEM equipment requiring a single coil variant across 100–250 V AC\/DC supply systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229134164251,"sku":"1SFL617001R7011","price":2097.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl617001r7011-af580-30-11-70-ac-dc-power-contactor_680ae3ad-cdb6-40ff-8615-276181305266.webp?v=1777160367","url":"https:\/\/stoklink.com\/products\/abb-1sfl617001r7011-af580-30-11-70-800a-contactor","provider":"Stoklink","version":"1.0","type":"link"}