{"product_id":"abb-1sda104958r1-yu-c-xt5-xt6-f-p-220-240vac-220-250vdc-under-voltage-coil","title":"ABB 1SDA104958R1 YU-C XT5-XT6 F\/P 220..240Vac-220..250Vdc Under Voltage Coil Tmax XT Fixed\/Plug-in","description":"\u003cp\u003eThe ABB 1SDA104958R1 YU-C XT5-XT6 F\/P 220..240Vac-220..250Vdc is an under voltage coil (UVR) designed for use with ABB Tmax XT5 and XT6 series moulded case circuit breakers in both fixed and plug-in mounting configurations. The YU-C XT5-XT6 F\/P 220..240Vac-220..250Vdc operates across a dual AC\/DC voltage range — 220–240 V AC and 220–250 V DC — enabling reliable tripping of the circuit breaker whenever the supply voltage drops below a preset threshold, protecting critical loads and motor circuits from damaging undervoltage conditions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYU-C XT5-XT6 F\/P 220..240Vac-220..250Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA104958R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT \/ XT5-XT6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYU-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder Voltage Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT5, Tmax XT6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed \/ Plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644070502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.143 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU machinery and low-voltage directive requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e EU Directive 2011\/65\/EU — restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU Directive 2015\/863 — compliance with chemical substance registration and restriction regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2 \/ UL 489:\u003c\/strong\u003e Manufactured and tested to international standards for low-voltage circuit breakers and accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Broader IEC standard covering low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive — product registered for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eProtection of motor circuits against harmful undervoltage conditions in industrial control panels\u003c\/li\u003e\n\u003cli\u003eIntegration into Tmax XT5 and XT6 circuit breakers for automatic tripping on voltage loss\u003c\/li\u003e\n\u003cli\u003eUse in building automation, manufacturing lines, and critical infrastructure where supply continuity monitoring is required\u003c\/li\u003e\n\u003cli\u003eFixed and plug-in MCCB installations requiring dual AC\/DC undervoltage release capability\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229079343387,"sku":"1SDA104958R1","price":56.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda104958r1-yu-c-xt5-xt6-f-p-220-240vac-220-250vdc-tmax-xt-fixed-plug-in_b06e2f57-0b7f-426d-b2e0-1a5ebeec89fe.webp?v=1777159455","url":"https:\/\/stoklink.com\/products\/abb-1sda104958r1-yu-c-xt5-xt6-f-p-220-240vac-220-250vdc-under-voltage-coil","provider":"Stoklink","version":"1.0","type":"link"}