{"product_id":"abb-1sda101171r1-xt7h-1000-ekip-dip-ls-i-in-1000a-4p-f-f","title":"ABB 1SDA101171R1 XT7H 1000 Ekip Dip LS\/I In=1000A 4p F F 70kA Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eABB's 1SDA101171R1 is the four-pole Tmax XT7H 1000 moulded case circuit breaker with a lever operating mechanism and an Ekip Dip LS\/I electronic release, rated In 1000 A with front terminals. Short-circuit performance class H gives it a 70 kA breaking capacity at 415 V AC and a 20 kA short-time withstand (Icw), matching the three-pole XT7H sibling but with a switchable neutral pole.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SDA101171R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eXT7H 1000 Ekip Dip LS\/I In=1000A 4p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8056221014748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-type\u003c\/td\u003e\n\u003ctd\u003eXT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mechanism\u003c\/td\u003e\n\u003ctd\u003eLever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LS\/I (electronic, type EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-240 V AC, 70 kA at 380-415 V AC, 65 kA at 440 V AC, 50 kA at 500-525 V AC, 42 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003eequal to Icu at all listed voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to 125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e37 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e280 x 268 x 166 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e12.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the four-pole 1SDA101171R1 over the three-pole 1SDA100891R1 whenever the distribution board switches the neutral through the breaker rather than running it on a solid bar; electrically the two share identical In, Icu, Ics and Icw ratings. The lever operating mechanism and 20 kA short-time withstand (Icw) carry over unchanged from the three-pole frame, the highest Icw figure in this XT5\/XT6\/XT7 group. At 12.5 kg and a wider 280 mm frame than the three-pole version, it needs correspondingly more panel depth and busbar clearance.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229075738907,"sku":"1SDA101171R1","price":2368.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda101171r1-xt7h-1000-ekip-dip-ls-i-mccb-4p.png?v=1790958802","url":"https:\/\/stoklink.com\/products\/abb-1sda101171r1-xt7h-1000-ekip-dip-ls-i-in-1000a-4p-f-f","provider":"Stoklink","version":"1.0","type":"link"}