{"product_id":"abb-1sda100891r1-xt7h-1000-ekip-dip-ls-i-in-1000a-3p-f-f","title":"ABB 1SDA100891R1 XT7H 1000 Ekip Dip LS\/I In=1000A 3p F F 70kA Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe ABB 1SDA100891R1 is a Tmax XT7H 1000 moulded case circuit breaker with a lever operating mechanism and an Ekip Dip LS\/I electronic release, rated In 1000 A across three poles with front terminals. Short-circuit performance class H gives it a 70 kA breaking capacity at 415 V AC and a 20 kA short-time withstand (Icw), the highest Icw in this XT5\/XT6\/XT7 lineup.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SDA100891R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eXT7H 1000 Ekip Dip LS\/I In=1000A 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8056221009454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-type\u003c\/td\u003e\n\u003ctd\u003eXT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mechanism\u003c\/td\u003e\n\u003ctd\u003eLever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LS\/I (electronic, type EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-240 V AC, 70 kA at 380-415 V AC, 65 kA at 440 V AC, 50 kA at 500-525 V AC, 42 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003eequal to Icu at all listed voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to 125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e37 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e210 x 268 x 166 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e9.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XT7H frame introduces a lever operating mechanism in place of the toggle handle used on the smaller XT4\/XT5\/XT6 frames, giving the breaker a 20 kA short-time withstand (Icw) - the highest in this lineup - alongside the same 70 kA Icu\/Ics at 415 V AC as the XT5H and XT6H H-class breakers. Three-pole construction without a neutral pole suits three-phase circuits; choose the four-pole 1SDA101171R1 variant when the neutral must be switched. A -40 to 125°C operating range extends beyond the unspecified ambient limits of the smaller frames, relevant for breakers mounted in unconditioned enclosures.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229054406939,"sku":"1SDA100891R1","price":1577.48,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda100891r1-xt7h-1000-ekip-dip-ls-i-mccb-3p.png?v=1790958647","url":"https:\/\/stoklink.com\/products\/abb-1sda100891r1-xt7h-1000-ekip-dip-ls-i-in-1000a-3p-f-f","provider":"Stoklink","version":"1.0","type":"link"}