{"product_id":"abb-1sda100777r1-xt6h-1000-ekip-dip-ls-i-in-1000-4p-f-f","title":"ABB 1SDA100777R1 XT6H 1000 Ekip Dip LS\/I In=1000 4p F F 70kA Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe ABB 1SDA100777R1 is a Tmax XT6H 1000 moulded case circuit breaker with an Ekip Dip LS\/I electronic release, rated In 1000 A across four poles with front terminals. Short-circuit performance class H gives it a 70 kA breaking capacity at 415 V AC, and the LS\/I electronic trip unit combines overload (L), short-time delay (S) and instantaneous (I) protection in one adjustable release.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SDA100777R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eXT6H 1000 Ekip Dip LS\/I In=1000 4p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8056221008310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-type\u003c\/td\u003e\n\u003ctd\u003eXT6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LS\/I (electronic, type EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-240 V AC, 70 kA at 380-415 V AC, 50 kA at 440-525 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003eequal to Icu at all listed voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e83.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e280 x 268 x 103.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt In 1000 A, the 1SDA100777R1 is the largest Ekip Dip LS\/I breaker in this XT6H group, sharing the same 10 kA short-time withstand (Icw) and 70 kA breaking capacity at 415 V AC as the 800 A sibling but built on the larger 280 x 268 mm XT6 frame to carry the higher current. The Ekip Dip LS\/I release still provides adjustable long-time, short-time and instantaneous trip settings, the same protection logic used across the XT5H and XT6H ranges. Choose it over the 800 A variant when the connected load genuinely needs the full 1000 A continuous rating, since both share the same release family and H performance class and differ mainly in frame current and weight.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229074428187,"sku":"1SDA100777R1","price":2320.72,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda100777r1-xt6h-1000-ekip-dip-ls-i-mccb.png?v=1790958590","url":"https:\/\/stoklink.com\/products\/abb-1sda100777r1-xt6h-1000-ekip-dip-ls-i-in-1000-4p-f-f","provider":"Stoklink","version":"1.0","type":"link"}