{"product_id":"abb-1sda100775r1-xt6h-800-tma-800-8000-4p-f-f-inn-100-in","title":"ABB 1SDA100775R1 XT6H 800 TMA 800-8000 4p F F InN=100%In 70kA Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe ABB 1SDA100775R1 is a Tmax XT6H 800 moulded case circuit breaker with a TMA thermomagnetic release, rated In 800 A across four poles with a fully rated neutral (InN=100%In). AC\/DC current type and short-circuit performance class H give it a 70 kA breaking capacity at 415 V AC, with an adjustable 560-800 A thermal band and 4000-8000 A instantaneous trip range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SDA100775R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eXT6H 800 TMA 800-8000 4p F F InN=100%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8056221008297\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-type\u003c\/td\u003e\n\u003ctd\u003eXT6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Setting Range\u003c\/td\u003e\n\u003ctd\u003e560-800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Trip Setting (Ii)\u003c\/td\u003e\n\u003ctd\u003e4000-8000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease\u003c\/td\u003e\n\u003ctd\u003eTMA (thermomagnetic, type TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Type\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC \/ 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-240 V AC, 70 kA at 380-415 V AC, 50 kA at 440-525 V AC, 25 kA at 690 V AC; 70 kA at 250 V DC (2 poles), 50 kA at 500 V DC (2 poles), 36 kA at 750 V DC (3 poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-240 V AC, 70 kA at 380-415 V AC, 50 kA at 440-525 V AC, 25 kA at 690 V AC; 35 kA at 250 V DC (2 poles), 25 kA at 500 V DC (2 poles), 18 kA at 750 V DC (3 poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e54.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e280 x 268 x 103.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1SDA100775R1 is the AC\/DC TMA counterpart of the 800 A Ekip Dip LS\/I breaker, sharing the same 10 kA short-time withstand (Icw) and 70 kA Icu\/Ics at 415 V AC but adding a 750 V DC rating for mixed-current or DC distribution boards. Its DC breaking capacity is asymmetric: the ultimate rating (Icu) reaches 70 kA at 250 V DC and 36 kA at 750 V DC in three-pole series, roughly double the corresponding service rating (Ics), so DC coordination studies should use the lower Ics figures rather than Icu. The adjustable 560-800 A thermal band and 4000-8000 A instantaneous trip give the same field-tunable protection as the smaller 400 A and 630 A TMA siblings, scaled to the XT6 frame.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229061681435,"sku":"1SDA100775R1","price":1833.51,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda100775r1-xt6h-800-tma-mccb.png?v=1790958548","url":"https:\/\/stoklink.com\/products\/abb-1sda100775r1-xt6h-800-tma-800-8000-4p-f-f-inn-100-in","provider":"Stoklink","version":"1.0","type":"link"}