{"product_id":"abb-1sda073252r1-e6-2v-5000-ekip-dip-lsi-4p-wmp","title":"ABB 1SDA073252R1 E6.2V 5000 Ekip Dip LSI 4p WMP 150kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA073252R1 is the E6.2V 5000 Ekip Dip LSI 4p WMP moving part for the SACE Emax 2 E6.2V air circuit breaker — a withdrawable insert rated 5000 A with a 150 kA breaking capacity at 400 V AC, built for 4-pole, 690 V AC drawout switchboards. It carries the Ekip Dip LSI electronic release and replaces or stocks the moving element of an already-installed E6.2V cradle.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA073252R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE6.2V 5000 Ekip Dip LSI 4p WMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644771027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e134 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e929 x 425 x 383 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Pole Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50% of Iu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In = Iu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated \/ Operational Voltage (Ur = Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity (Icu = Ics, 100%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA (400-440 V AC) | 130 kA (500-525 V AC) | 100 kA (690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA for 1 s \/ 100 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis WMP is the moving part for the 5000 A, 150 kA E6.2V frame. Its Ekip Dip LSI release is the three-function version — L (overload, long-time), S (short-time delay), I (instantaneous) — so the breaker can hold a developing downstream fault open long enough for a smaller device to trip first. That selectivity makes it the right choice for an incomer or bus-tie, not a feeder end-point; where instantaneous clearing matters more than selectivity, the Ekip Dip LI sibling at the same 5000 A rating is the one to specify. Its V-class short-circuit performance level raises Icu to 150 kA between 400 and 440 V AC, tapering to 130 kA at 500-525 V and 100 kA at 690 V — specify it over the H-class sibling's flat 100 kA only when the calculated prospective fault current calls for that extra margin. With a fourth pole, the neutral is also switched — rated at 50% of the phase current, enough for TN distribution where the neutral carries only unbalance load.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228984643867,"sku":"1SDA073252R1","price":21079.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda073252r1-e6-2v-5000-ekip-dip-lsi-4p-wmp-air-circuit-breaker.jpg?v=1790957785","url":"https:\/\/stoklink.com\/products\/abb-1sda073252r1-e6-2v-5000-ekip-dip-lsi-4p-wmp","provider":"Stoklink","version":"1.0","type":"link"}