{"product_id":"abb-1sda073012r1-e2-2n-2000-ekip-dip-lsi-4p-wmp","title":"ABB 1SDA073012R1 E2.2N 2000 Ekip Dip LSI 4p WMP 66kA Air Circuit Breaker","description":"\u003cp\u003eABB's 1SDA073012R1 covers the four-pole point in the SACE Emax 2 E2.2N 2000 Ekip Dip LSI line: 2000 A rated current, four poles with a 100%-rated neutral, and 66 kA breaking capacity at 400 V AC. The LSI release pairs long-time overload and instantaneous protection with an adjustable short-time delay for coordinated tripping.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA073012R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N 2000 Ekip Dip LSI 4p WMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644768621\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Pole Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% of Iu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUltimate Breaking Capacity (Icu, 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity (Ics, 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA (100% of Icu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA for 1 s \/ 50 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease \/ Trip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithdrawable moving part (WMP) - separate fixed part\/cradle required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, up to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e407 x 425 x 383 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fourth pole carries the same 100% rated current as the phases, so this version suits a solidly-grounded or TT distribution board where the neutral must be switched and protected to the same 2000 A rating as the phases. Against the three-pole 1SDA072382R1 in the same N\/LSI combination, pick this 4P unit when the installation needs a switched and breaking neutral rather than a fixed or unprotected one. It remains a WMP unit, so a matching E2.2 fixed part has to be installed in the cubicle first.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228981301531,"sku":"1SDA073012R1","price":5489.96,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda073012r1-e2-2n-2000-ekip-dip-lsi-4p-wmp-air-circuit-breaker.jpg?v=1790954469","url":"https:\/\/stoklink.com\/products\/abb-1sda073012r1-e2-2n-2000-ekip-dip-lsi-4p-wmp","provider":"Stoklink","version":"1.0","type":"link"}