{"product_id":"abb-1sda072932r1-e2-2n-1250-ekip-dip-lsi-4p-wmp","title":"ABB 1SDA072932R1 E2.2N 1250 Ekip Dip LSI 4p WMP 66kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA072932R1 is an air circuit breaker moving part: a SACE Emax 2 E2.2N 1250, four-pole, Ekip Dip LSI electronic release, rated 1250 A uninterrupted current and 66 kA breaking capacity at 400 V AC. It ships as a WMP, so a compatible fixed part is a separate purchase before it can be installed.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA072932R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N 1250 Ekip Dip LSI 4p WMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644767822\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame \/ Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N (level N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Pole Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% of In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In \/ Iu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Breaking Capacity (Icu) at 400 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Breaking Capacity (Ics) at 400 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA (100% of Icu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA \/ 1 s, 50 kA \/ 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease \/ Trip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (per pole)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e407 x 425 x 383 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, up to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eCarrying the S function, this Ekip Dip LSI release can be set with a short-time delay so the breaker rides through a downstream fault and lets a smaller device clear it first — the reason to choose it over the plain LI release wherever this unit needs to coordinate selectively with other breakers on the installation. 66 kA Icu and 66 kA Icw for 1 second mark it as the N performance level, a lower fault-current rating than the H-level E2.2 frame and typically the lower-cost option when the switchboard's available fault current does not require it. As a WMP, order the matching fixed part separately; together they form a withdrawable breaker that can be pulled for maintenance without touching the wiring. At 1250 A this sits below the 1600 A and 2000 A E2.2N siblings in the same release and pole count.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228981137691,"sku":"1SDA072932R1","price":4177.51,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda072932r1-e2-2n-1250-ekip-dip-lsi-4p-wmp-air-circuit-breaker.jpg?v=1790954374","url":"https:\/\/stoklink.com\/products\/abb-1sda072932r1-e2-2n-1250-ekip-dip-lsi-4p-wmp","provider":"Stoklink","version":"1.0","type":"link"}