ABB SACE Emax 2 Air Circuit Breaker: Selection, Application and Maintenance Guide
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
SACE Emax 2 E6.2H ACB, 6300 A, 100 kA Icu, 3-pole, Ekip Dip LI, WMP.
Rated 6300 A with a 100 kA breaking capacity at 400 V AC, the ABB 1SDA072641R1 is the E6.2H 6300 Ekip Dip LI 3p WMP withdrawable moving part of the SACE Emax 2 E6.2H frame. The Ekip Dip LI electronic release handles 3-pole protection up to 690 V AC, and the part is sized to rack into an existing E6.2H drawout cradle rather than a fixed enclosure.
This 6300 A, 100 kA E6.2H unit is the drawout moving part that racks into the Emax 2 cradle. The Ekip Dip LI release limits it to L (overload, long-time), I (instantaneous) — there is no adjustable short-time delay to hold through a downstream fault. That suits a feeder position where fast, instantaneous clearing is preferred over coordination with a smaller breaker below it; for an incomer or bus-tie needing that coordination, the Ekip Dip LSI sibling at the same 6300 A rating adds the S function. At the H short-circuit performance level, Icu stays a flat 100 kA across the full 400-690 V AC range; if the prospective fault current here runs higher than that, move up to the V-class sibling, rated 150 kA at 400-440 V AC.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Product Net Width | 803 mm |
|---|---|
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 120 kg |
| Product Main Type | SACE Emax 2 |
|---|---|
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Part number | 1SDA072641R1 |
|---|---|
| Type designation | E6.2H |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 8015644764913 |
| ETIM class | EC000228 |
| eCl@ss | 27370409 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Connecting Capacity | 6000 mm² |
|---|---|
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 2000 cycle, Ue = 500 ... 690 V 2000 cycle, 10 cycles per hour |
| Mechanical Durability | 12000 cycle, 60 cycles per hour |
| Number of Poles | 3P |
| Power Loss | 1550 W |
| Rated Current (In) | 6300 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA, (230 V AC) 100 kA, (380 V AC) 100 kA, (400 V AC) 100 kA, (415 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (660 V AC) 100 kA, (690 V AC) 100 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA, for 3 s 100 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA, (415 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (525 V AC) 100 kA, (690 V AC) 100 kA |
| Rated Uninterrupted Current (Iu) | 6300 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
|---|---|
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1000 mm |
| Package Level 1 Gross Weight | 129 kg |
| Package Level 1 EAN | 8015644764913 |
| Shipping weight | 120.0 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of E6.2H is 6300 A.
The rated operational voltage of E6.2H is 690 V AC.
The tariff (HS) code on file for E6.2H is 853620.
The EAN (GTIN) of E6.2H is 8015644764913.
E6.2H ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
Select the correct ABB Emax 2 Ekip trip unit with this guide to LI, LSI, LSIG codes, frame sizing, and measurement classes for switchgear....
Compare ABB Emax 2, Schneider MasterPact MTZ, and Siemens 3WL air circuit breakers by ratings, features, IEC 60947 compliance, and price. Shop at Stoklink.