Part number
1SDA072641R1
Model no
E6.2H
$17,893.43 On request Dispatch — · From TürkiyeGet a Quote

ABB 1SDA072641R1 E6.2H 6300 Ekip Dip LI 3p WMP 100kA Air Circuit Breaker

SACE Emax 2 E6.2H ACB, 6300 A, 100 kA Icu, 3-pole, Ekip Dip LI, WMP.

Rated current
6300 A
Rated operational voltage
690 V AC
Poles
3P
Breaking capacity
100 kA
EAN
8015644764913
Description

About the E6.2H

Rated 6300 A with a 100 kA breaking capacity at 400 V AC, the ABB 1SDA072641R1 is the E6.2H 6300 Ekip Dip LI 3p WMP withdrawable moving part of the SACE Emax 2 E6.2H frame. The Ekip Dip LI electronic release handles 3-pole protection up to 690 V AC, and the part is sized to rack into an existing E6.2H drawout cradle rather than a fixed enclosure.

Selection Notes

This 6300 A, 100 kA E6.2H unit is the drawout moving part that racks into the Emax 2 cradle. The Ekip Dip LI release limits it to L (overload, long-time), I (instantaneous) — there is no adjustable short-time delay to hold through a downstream fault. That suits a feeder position where fast, instantaneous clearing is preferred over coordination with a smaller breaker below it; for an incomer or bus-tie needing that coordination, the Ekip Dip LSI sibling at the same 6300 A rating adds the S function. At the H short-circuit performance level, Icu stays a flat 100 kA across the full 400-690 V AC range; if the prospective fault current here runs higher than that, move up to the V-class sibling, rated 150 kA at 400-440 V AC.

Specification

Full specification

57 values · Last verified 02 Oct 2026

Material Compliance 1

RoHS Information Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Dimensions 4

Product Net Width 803 mm
Product Net Height 425 mm
Product Net Depth / Length 383 mm
Product Net Weight 120 kg

Additional Information 4

Product Main Type SACE Emax 2
Product Name Air Circuit Breaker
Product Type Air Circuit Breaker
Version W
Show all 57 specifications ↓ Show less ↑48 more values in Identification, Technical, External Classifications and Standards, Logistics.

Identification 11

Part number 1SDA072641R1
Type designation E6.2H
Brand ABB
Condition New, factory sealed
Source ABB and its authorised distributors
Warranty Manufacturer warranty
EAN 8015644764913
ETIM class EC000228
eCl@ss 27370409
Minimum Order Quantity 1 piece
Customs Tariff Number 85362090

Technical 23

Connecting Capacity 6000 mm²
Current Type AC
Electrical Durability Ue =< 440 V 2000 cycle, Ue = 500 ... 690 V 2000 cycle, 10 cycles per hour
Mechanical Durability 12000 cycle, 60 cycles per hour
Number of Poles 3P
Power Loss 1550 W
Rated Current (In) 6300 A
Rated Impulse Withstand Voltage (Uimp) acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui) AC 1000 V
Rated Operational Voltage 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics) (220 V AC) 100 kA, (230 V AC) 100 kA, (380 V AC) 100 kA, (400 V AC) 100 kA, (415 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (660 V AC) 100 kA, (690 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) 100 %
Rated Short-time Withstand Current Low Voltage (Icw) for 1 s 100 kA, for 3 s 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (400 V AC) 100 kA, (415 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (525 V AC) 100 kA, (690 V AC) 100 kA
Rated Uninterrupted Current (Iu) 6300 A
Rated Voltage (Ur) 690 V
Recommended Screw Driver M12
Release Ekip Dip LI
Release Type EL
Short-Circuit Performance Level H
Standards IEC
Sub-type E6.2
Suitable for IT Networks Yes, 690V

External Classifications and Standards 4

ETIM 10 EC000228 - Power circuit-breaker for trafo/generator/installation protection
UNSPSC 39121615
WEEE Category 4. Large Equipment (Any External Dimension More Than 50 cm)
eClass V11.1 : 27370409

Logistics 10

Package Level 1 Units box 1 piece
Package Level 1 Width 515 mm
Package Level 1 Height 610 mm
Package Level 1 Depth / Length 1000 mm
Package Level 1 Gross Weight 129 kg
Package Level 1 EAN 8015644764913
Shipping weight 120.0 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 02 Oct 2026

Documents

Documents for 1SDA072641R1

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • IEC
Quick answers

Questions about the E6.2H

What is the rated current of E6.2H?

The rated current of E6.2H is 6300 A.

Which supply voltage is E6.2H rated for?

The rated operational voltage of E6.2H is 690 V AC.

What is the HS code of E6.2H for customs?

The tariff (HS) code on file for E6.2H is 853620.

What is the EAN of E6.2H?

The EAN (GTIN) of E6.2H is 8015644764913.

Where does E6.2H ship from, and how fast?

E6.2H ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for ACB

All guides for ACB
Reviews

Customer reviews

Series

ABB ABB Emax 2

Brand
ABB
Series
ABB Emax 2
Series page →
Series

Other series in Air Circuit Breakers (ACB)

$17,893.43 On request
Get a Quote
Quote

Get a Quote

E6.2H

Genuine parts

Genuine, factory-sealed parts

ABB · 1SDA072641R1

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
ABB and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart