{"product_id":"abb-1sda072612r1-e6-2h-5000-ekip-dip-lsi-3p-wmp","title":"ABB 1SDA072612R1 E6.2H 5000 Ekip Dip LSI 3p WMP 100kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA072612R1 is the E6.2H 5000 Ekip Dip LSI 3p WMP moving part for the SACE Emax 2 E6.2H air circuit breaker — a withdrawable insert rated 5000 A with a 100 kA breaking capacity at 400 V AC, built for 3-pole, 690 V AC drawout switchboards. It carries the Ekip Dip LSI electronic release and replaces or stocks the moving element of an already-installed E6.2H cradle.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA072612R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE6.2H 5000 Ekip Dip LSI 3p WMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644764623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e803 x 425 x 383 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In = Iu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated \/ Operational Voltage (Ur = Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity (Icu = Ics, 100%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA (400-690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA for 1 s \/ 100 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis WMP is the moving part for the 5000 A, 100 kA E6.2H frame. Its Ekip Dip LSI release adds the S function (L (overload, long-time), S (short-time delay), I (instantaneous)) on top of the base L and I protections. The adjustable short-time delay lets it hold through a downstream fault long enough for a smaller breaker to clear first, which is why this release is specified for incomer and bus-tie positions rather than the end of a feeder run. Pick the Ekip Dip LI sibling at the same 5000 A rating when the breaker sits further downstream and instantaneous clearing is acceptable. The H performance level holds a flat 100 kA breaking capacity from 400 V through 690 V AC; where the calculated fault level at this point exceeds that, the V-class sibling at 150 kA (400-440 V AC) is the one to specify instead.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228921041179,"sku":"1SDA072612R1","price":15982.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda072612r1-e6-2h-5000-ekip-dip-lsi-3p-wmp-air-circuit-breaker.jpg?v=1790957325","url":"https:\/\/stoklink.com\/products\/abb-1sda072612r1-e6-2h-5000-ekip-dip-lsi-3p-wmp","provider":"Stoklink","version":"1.0","type":"link"}