ABB SACE Emax 2 Air Circuit Breaker: Selection, Application and Maintenance Guide
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
ABB 1SDA072222R1 — SACE Emax 2 1600 A air circuit breaker, Ekip Dip LSI, 3P, Icu 50 kA, Withdrawable.
ABB's SACE Emax 2 1SDA072222R1 air circuit breaker delivers 1600 A rated current with Ekip Dip LSI electronic release, three poles, and withdrawable moving part (WMP) mounting. It carries a 50 kA ultimate breaking capacity (Icu) at 400 V AC and a 1 s short-time withstand (Icw) of 42 kA, rated up to 690 V AC.
With Ekip Dip LSI at 1600 A, this three-pole withdrawable breaker holds through a downstream fault for up to 1 s at its 42 kA Icw rating, the basis for selective coordination ahead of smaller feeder breakers. It racks into a cradle as the moving part (WMP) rather than bolting in fixed, which allows isolation and swap-out without disturbing the busbar. Unlike the four-pole sibling, it leaves the neutral unswitched. The 400 W power loss at this current and frame is the same whether configured with three or four poles.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Product Net Width | 278 mm |
|---|---|
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Product Main Type | SACE Emax 2 |
|---|---|
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Part number | 1SDA072222R1 |
|---|---|
| Type designation | E1.2C |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 8015644760724 |
| ETIM class | EC000228 |
| eCl@ss | 27370409 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Connecting Capacity | 1200 mm² |
|---|---|
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle, Ue = 500 ... 690 V 6500 cycle, 30 cycles per hour |
| Mechanical Durability | 20000 cycle, 60 cycles per hour |
| Number of Poles | 3P |
| Power Loss | 400 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA, (230 V AC) 50 kA, (380 V AC) 50 kA, (400 V AC) 50 kA, (415 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 42 kA, (660 V AC) 42 kA, (690 V AC) 42 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA, for 3 s 24 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA, (415 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 42 kA, (525 V AC) 42 kA, (690 V AC) 42 kA |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
|---|---|
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760724 |
| Shipping weight | 18.0 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of E1.2C is 1600 A.
The rated operational voltage of E1.2C is 690 V AC.
The tariff (HS) code on file for E1.2C is 853620.
The EAN (GTIN) of E1.2C is 8015644760724.
E1.2C ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
Select the correct ABB Emax 2 Ekip trip unit with this guide to LI, LSI, LSIG codes, frame sizing, and measurement classes for switchgear....
Compare ABB Emax 2, Schneider MasterPact MTZ, and Siemens 3WL air circuit breakers by ratings, features, IEC 60947 compliance, and price. Shop at Stoklink.